PAMS Technical Documentation NSE–5 Series Transceivers Service Tools Issue 1 07/99
NSE–5 Service Tools PAMS Technical Documentation CONTENTS Page No Battery Adapter BDC–3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Service Battery BBD–3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Module Jig MJS–8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Audio Test Probe MPA–1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NSE–5 PAMS Technical Documentation Service Tools Battery Adapter BDC–3 The Battery Adapter BDC–3 is used along with an external battery capacity meter to check battery capacity. Note that Li–ion batteries have an internal protection circuit to prevent deep discharge.
NSE–5 PAMS Service Tools Technical Documentation Service Battery BBD–3 The Service Battery BBD–3 is used in place of the phone’s normal battery during service, to supply a controlled operating voltage to the phone for current and charger calibration, and is also required when flashing the phone. Note that the cable SCB–3 (0730114) is also required for charger calibration.
NSE–5 PAMS Technical Documentation Service Tools Module Jig MJS–8 The Module Jig MJS–8 is used for component level repair of the system/RF module. * Product Code Module Jig MJS–8: 0775170 View of MJS–8 *) Connect the External antenna cable XRC–1B, service Cable SCH–5, and the DC Cable PCS–1 to the MJS–8 jig. The service cable SCH–5 can be replaced by the DAU–9P cable. Note: Issue 1 07/99 The nominal supply voltage for MJS–8 is +4.1 V. The supply voltage must not exceed +6.0 V.
NSE–5 PAMS Technical Documentation Service Tools Audio Test Probe MPA–1 MPA–1 is a Audio Test Probe used for testing the microphone signal together with the Module Jig MJS–8.
NSE–5 PAMS Technical Documentation Service Tools Flash Loading Adapter FLA–5 (Sales Pack) The Flash Loading Adapter FLA–5 is used with the Service Battery BBD–3 and Service Cable SCH–5. Power is supplied to FLA–5 from the Flash Security Box TDF–4 via the DC cable PCC–1B, (The PCC–1B cable can be replaced with a Travel Charger ACH–6), and is connected to the Flash Prommer FPS–4S with the cable AXS–5.
NSE–5 PAMS Service Tools Technical Documentation Flash Prommer FPS–4S (Sales Pack) The Flash Prommer FPS–4S is used to update the main software of the phone. Updating is done by first loading the new MCU software from the PC to the flash prommer, and then loading the new SW from the prommer to the phone. When updating more than one phone in succession, the MCU software only needs to be loaded to the prommer once.
NSE–5 PAMS Technical Documentation Service Tools Security Box TDF–4 The Security Box TDF–4 is required for updating MCU software, and infra red testing. Note1: TDF–4 is delivered in de–activated mode.
NSE–5 PAMS Service Tools Technical Documentation Service Audio Box JBA–4 The Service Audio Box JBA–4 is used between the Service Cable SCH–5, MBUS Cable DAU–9S, and Audio Cable ADS–1.
NSE–5 PAMS Technical Documentation Service Tools Service Cable SCH–5 The Service Cable SCH–5 is used between the phone and Service Audio Box JBA–4 (or modular T–adapter. It is also used between the phone and the Flash Loading Adapter FLA–5.
NSE–5 PAMS Service Tools Technical Documentation Warranty Cable SCH–6 The Warranty cable SCH–6 is used to connect two phones, and enables transfer of data (stored numbers etc.) from one phone to another.
NSE–5 PAMS Technical Documentation Service Tools Audio Cable ADS–1 Audio cable is an adapter routing AF signals (MIC/EAR) from 8 pin modular connector to two BNC connectors. It is used to connect JBA–4, SCH–5, and DAU–9S.
NSE–5 PAMS Service Tools Technical Documentation D15–D15 Cable AXS–5 The D15–D15 Cable AXS–5 is used to connect two 15 pin D connectors. e.g. between FLA–5 and FPS–4S.
NSE–5 PAMS Technical Documentation Service Tools DC Cable PCC–1B The DC Cable PCC–1B is used e.g. to connect FLA–5 and TDF–4.
NSE–5 PAMS Technical Documentation Service Tools DC Cable SCB–3 The DC Cable SCB–3 is used to connect the Service Battery to the charger connection Vin of the phone when doing the charger calibration service procedure.
NSE–5 PAMS Technical Documentation Service Tools External Antenna Cable XRC–1B The External Antenna Cable is used to connect the transceiver to measuring equipment during servicing. Note: Typical attenuation at 900 MHz is 0.7 dB. Typical attenuation at 1800 MHz is 0.9 dB.
NSE–5 PAMS Service Tools Technical Documentation MBUS Cable DAU–9S The MBUS Cable DAU–9S has a modular connector, and is used with the service Audio Box JBA–4, or a modular T–adapter.
NSE–5 PAMS Technical Documentation Service Tools MBUS Cable DAU–9P The MBUS Cable DAU–9P has a phone system connector, and is used between the phone and external devices.
NSE–5 PAMS Service Tools Technical Documentation Power Cable PCS–1 The Power Cable PCS–1 is used to connect the module jigs JBT–1 and JBS–19 to an external power supply.
NSE–5 PAMS Technical Documentation Service Tools Modular T–adapter The modular T–adapter is a suitable branching unit to provide the needed parallel modular connections.
NSE–5 PAMS Service Tools Technical Documentation SW Security Device PKD–1 SW security device is a piece of hardware enabling the use of the service software when connected to the parallel (LPT) port of the PC. Whitout the dongle present it is not possible to use the service software. Printer or any such device can be connected to the PC through the dongle if needed.
NSE–5 PAMS Technical Documentation Service Tools Dongle/Flash Device FLS–1 (Sales Pack) FLS–1 is a dongle and flash device incorporated into one package, developed specifically for POS use.
NSE–5 PAMS Technical Documentation Service Tools FLS–1 Connection Diagram 1.