User Guide

PAMS
Technical Documentation
NSE–5
Troubleshooting
Page 4
Issue 1 07/99
1. Phone is totally dead
This means that phone doesn’t take current at all when the power switch
is pressed (X400 pin 7) or when the watchdog disable pin (X201 pin 11) is
grounded. Used battery voltage must be higher than 3.1 V. Otherwise the
hardware of CCONT (N100) prevents totally to switch power on.
Phone is totally dead.
Measure voltage at
C155 (VBAT)
3.6V
Measure voltage at
C153
3.6V
Power doesn’t stay on.
No
Ye s
Ye s
No
Failure in VBAT.
Check X101, X102,
L103, L102, R102
Measure voltage at R413 (end
towards edge) when pwr–switch
(X400 pin 7) is pressed or
WDOGDISABLE (X201 pin 11)
is grounded.
0V
(Will be low only during
power–up of CCONT if
power switch is pressed.)
Measure voltage at V113 pin 4
(Vbb) 2.8V
C112 (end towards bottom) (VXO)
2.8V
When PWR switch is pressed or
WDOGDISABLE is grounded.
Voltages OK?
No
Ye s
Check R413, V410
Check LCD–module
Check WDOGDISABLE line
Ye s
No
Faulty PCB
Faulty PCB
Figure 1.