User Guide

Results
By measuring with an oscilloscope at RXIP or RXQP on a working GSM1900 receiver this picture should be
seen. Signal amplitude 108 mVp-p. DC offset 1.0V.
Figure 60 1900 RX I/Q signal waveform
Measurement points in the receiver
Figure 61 RX measurements point of the control voltages to FEM N7700
RH-116; RH-117
RF Troubleshooting Instructions
Issue 1 COMPANY CONFIDENTIAL Page 4 –31
Copyright © 2008 Nokia. All rights reserved.