CCS Technical Documentation RH-26 Series Transceivers 5 - Service Tools Issue 1 02/04 ©Nokia Corporation
RH-26 5 - Service Tools CCS Technical Documentation [This page left intentionally blank] Page 2 ©Nokia Corporation Issue 1 02/04
RH-26 5 - Service Tools CCS Technical Documentation Table of Contents Page No JVB-1 Docking Station and DA-6 Adapter ................................................................... 5 SA-15 Antenna Coupler................................................................................................. 7 MJ-5 Module Test Jig .................................................................................................... 8 RJ-4 Soldering Jig............................................................
RH-26 5 - Service Tools CCS Technical Documentation [This page left intentionally blank] Page 4 ©Nokia Corporation Issue 1 02/04
RH-26 5 - Service Tools CCS Technical Documentation JVB-1 Docking Station and DA-6 Adapter The JVB-1 docking station has been designed for calibration and software update purposes. The DA-6 docking station adapter establishes signal connections to the phone. JVB-1 and DA-6 are used as one unit.
RH-26 5 - Service Tools CCS Technical Documentation View of JVB-1 View of DA-6 Page 6 ©Nokia Corporation Issue 1 02/04
RH-26 5 - Service Tools CCS Technical Documentation SA-15 Antenna Coupler RF antenna coupler is used together with DA-6 docking station adapter. When used with DA-6, SA-15 enables RF function tests in GSM bands 850, 1800 and 1900 MHz.
RH-26 5 - Service Tools CCS Technical Documentation MJ-5 Module Test Jig Module test jig MJ-5 is designed for TB6 module testing. It can be used for flashing and RF-, battery-, system-, radio- and SIM reader testing. Product code MJ-5 module test jig: 0770651 View of MJ-5 The nominal supply voltage for MJ-5 is 4-12 VDC.
RH-26 5 - Service Tools CCS Technical Documentation RJ-4 Soldering Jig RJ-4 soldering jig is used for soldering and as a rework jig for TB6 module.
RH-26 5 - Service Tools CCS Technical Documentation SS-14 Domesheet Assembly Jig SS-14 domesheet is a jig for domesheet assembly. It is used for the right-hand side qwerty-keyboard.
RH-26 5 - Service Tools CCS Technical Documentation SES-3 Rework Kit The SES-3 rework kit is used for PA chip (LGA type component) rework and includes rework Jig MJS-76, SES-3 stencil and SPS-1 soldering paste spreader.
RH-26 5 - Service Tools CCS Technical Documentation FPS-8 Flash Prommer (Sales Pack) The flash prommer FPS-8 is used with e.g. DA-6 and JVB-1. Power is supplied to FPS-8 from the universal power supply.
RH-26 5 - Service Tools CCS Technical Documentation FPS-8C Parallel Flash Prommer (Sales Pack) The parallel flash prommer FPS-8C is used with DA-6 and JVB-1. With FPS-8C, flash programming can be done to a maximum of 8 phones. FPS-8C consists of eight SF11C programming cards. SF11C card is functionally identical to FPS-8.
RH-26 5 - Service Tools CCS Technical Documentation ACF-8 Universal Power Supply ACF-8 universal power supply is used to power FPS-8. ACF-8 has 6 V DC and 2.1 A output.
RH-26 5 - Service Tools CCS Technical Documentation SF-5 POS (Point Of Sales) Flash Adapter SF-5 POS flash adapter is used in POS (Point of Sales) environment for software updating. It provides controlled supply voltage and necessary connections between the phone and the flash prommer. It substitutes for the phone’s standard battery during the software update.
RH-26 5 - Service Tools CCS Technical Documentation FLC-2 DC Cable The FLC-2 is used to supply an operating voltage to SF-5 POS adapter when used with the FPS-8 flash prommer.
RH-26 5 - Service Tools CCS Technical Documentation AXS-4 Service Cable The AXS-4 D9-D9 service cable is used to connect two 9 pin D connectors e.g. between PC and FPS-8. Cable length is 2 meters.
RH-26 5 - Service Tools CCS Technical Documentation XCS-1 Service Cable The XCS-1 service cable is used to connect FLS-4S to SF-5.
RH-26 5 - Service Tools CCS Technical Documentation PKD-1 SW Protection Key SW protection device (dongle) is a piece of hardware enabling the use of the service software when connected to the parallel (LPT) port of the PC. Without the dongle it is not possible to use the service software. Printer or any such device can be connected to the PC through the dongle if needed.
RH-26 5 - Service Tools CCS Technical Documentation FLS-4S POS (Point Of Sales) Flash Prommer (Sales Pack) FLS-4S is a dongle and flash prommer incorporated into one package, developed for POS use.
RH-26 5 - Service Tools CCS Technical Documentation PCS-1 Power Cable The PCS-1 power cable (DC) is used to e.g. connect JVB-1 to FPS-8 or MJS-5 to external power supply.
RH-26 5 - Service Tools CCS Technical Documentation XRF-1 RF Cable RF cable XRF-1 is used to connect e.g. the module jig MJ-5 to RF measurement equipment.
RH-26 5 - Service Tools CCS Technical Documentation DAU-9S MBUS Cable The MBUS Cable DAU-9S has a modular connector, and it is used between PC's serial port and e.g. module jig MJ-5.
RH-26 5 - Service Tools CCS Technical Documentation CA-55 DC Cable The DC cable CA-55 is used to connect e.g. JVB-1 to the phone charging connector during energy management calibration. The older SCB-3 cable can be used for this purpose as well.
RH-26 5 - Service Tools CCS Technical Documentation XCS-4 Modular Cable XCS-4 is a shielded cable modular cable for flashing and service purposes.
RH-26 5 - Service Tools CCS Technical Documentation Printer Cable This cable is used to connect the PC to FPS-8.
RH-26 5 - Service Tools CCS Technical Documentation JBT-9 Bluetooth Test Box Bluetooth test and interface box JBT-9 can be used to test the Bluetooth functionality of phones. It also works as a wireless service interface for Bluetooth phones serviced with Phoenix. Usage: • Stand alone usage as loop-back device for BER testing supported by Phoenix. • RF attenuation can be set via jumpers. • SMA antenna connector for SMA antenna or repair jig.