User Guide

RH-26 Company Confidential
5 - Service Software Instructions CCS Technical Documentation
Page 72 Copyright ©Nokia. All rights reserved. Issue 1 02/04
GSM1900 PA high mode with EDGE on
25 Set Power Meter (or Spectrum analyzer) as required.
26 Repeat the same steps as for EGSM High and Low Mode above.
When EDGE is on, the tuning must be made for all power levels.
27 Tune base level and all power levels from 15 to 2 to target level.
28 When tuning values are correct, click “Save & Continue”.
The values are saved to phone’s memory.
29 To end tuning, close the “TX Power Level Tuning” dialog.
Typical values: EGSM850
Typical values: GSM1800
Typical values: GSM1900
Power
level
PA high mode PA low mode
5 0.700…0.850 -
7 - 0.500…0.600
15 0.210…0.230 0.210…0.230
19 0.180…0.200 0.180…0.200
Base 0.150…0.170 0.150…0.170
Power level PA high mode
0 0.700…0.800
11 0.180…0.230
15 0.150…0.200
Base 0.150…0.170
Power level PA high mode
0 0.800…0.900
11 0.180…0.230
15 0.150…0.200
Base 0.150…0.170