User Guide

RH-26 Company Confidential
5 - Service Software Instructions CCS Technical Documentation
Page 70 Copyright ©Nokia. All rights reserved. Issue 1 02/04
The tuning value can be adjusted with “-“ and “+” keys.
6 When tuning values are correct, click “Save & Continue”.
If all coefficients are within specified limits, tuning continues on the EGSM850
PA Low Mode with EDGE off.
EGSM850 PA low mode with EDGE off
This tuning step is not required for the RH-26 product, phone will not react to any con-
trols.
7 Click “Save & Continue”.
If all coefficients are within specified limits, tuning will continue on the
EGSM850 PA High Mode with EDGE on.
EGSM 850 PA high mode with EDGE on
8 Set power meter (or spectrum analyzer) as required.
9 Repeat the same steps as for EGSM High and Low Mode above.
When EDGE is on, tuning must be made for all power levels.
10 Tune base level and all power levels from 19 to 8 to target level.
11 When tuning values are correct, click “Save & Continue”.
If all coefficients are within specified limits, tuning continues on the EGSM850