10 Set 8th required frequency and level => OK.
11 Set 9th required frequency and level => OK.
Tuning values and ADC readings are displayed.
Typical values and limits in Rx Band Filter Response Compensation
EGSM850:
12 Tuning continues automatically in the next band (GSM1800) when you click
“Save & Continue”.
Channel Input frequency (MHz) Measured level difference (dB) Limits (dB)
965 923.26771 -1.266 -10…+3.5
975 925.26771 -0.641 -3.5…+3.5
987 927.66771 -0.188 -3.5…+3.5
1009 932.06771 -0.094 -3.5…+3.5
37 942.46771 -0.188 -3.5…+3.5
90 953.06771 0.391 -3.5…+3.5
114 957.86771 -0.266 -3.5…+3.5
124 959.86771 -0.359 -3.5…+3.5
136 962.26771 -0.453 -10…+3.5