User Guide
RH-26 Company Confidential
5 - Service Software Instructions CCS Technical Documentation
Page 54 Copyright ©Nokia. All rights reserved. Issue 1 02/04
Calibrating GSM1800 band
5 When asked, set RF generator to the required GSM 1800 frequency => OK.
Tuning values and ADC readings are displayed.
Typical values and limits in (GSM1800) RX Calibration:
6 Tuning automatically continues to the next band (GSM1900) when you click
“Save & Continue”.
GSM1800 Typical value Limits
RSSI0 62.40625 58…68
RSSI1 68.40625 64…74
RSSI2 74.265625 70…80
RSSI3 80.265625 76…86
RSSI4 86.265625 82…92
RSSI5 91.859375 88…98
RSSI6 97.859375 94…104
RSSI7 103.71875 100…110
RSSI8 109.71875 106…116
RSSI9 115.71875 112…122
RSSI10 121.71875 118…128
RSSI11 127.71875 124…134
RSSI12 133.71875 130…140
RSSI13 139.71875 136…146
RSSI14 145.71875 142…152