User Guide
Nokia Customer Care 6(a) - Baseband Troubleshooting
Company Confidential RH-51/52, RH-67/68
Issue 3 09/2004 © 2004 Nokia Corporation. Page 49
Baseband tuning operation
Energy managment calibration is always required when the following components are
changed.
• charging related components
• ZOCUS (N130) and related components
• UEME (D250) and related components
• BSI related components
Energy management calibration
EM (Energy Management) calibration is performed to calibrate the setting (gain and off-
set) of AD converters in several channels (i.e. battery voltage, BSI, charger voltage,
charger current).
This is to get accurate conversion result of AD converter.
HW setup
“JBV-1 service concept” is needed.
An external power supply is needed.
The RH-51/52, RH-67/68 phone must be connected to JBV-1 (docking station) with DA-
18 (docking station adapter).
• Connect SCB-3 (DC-DC cable) between JBV-1 and charger connector of phone for
charger channel calibration.
• Supply 11-16V DC from an external power supply to JBV-1 to power up phone.
Phoenix SW setup
• Start Phoenix service software.
• Select FBUS connection.
• Choose Main -> Choose product-> RH-51, -52, -67 or -68.
• Choose Tuning -> Energy Management Calibration.