User Guide

Nokia Customer Care 6(a) - Baseband Troubleshooting
Company Confidential RH-51/52, RH-67/68
Issue 3 09/2004 © 2004 Nokia Corporation. Page 49
Baseband tuning operation
Energy managment calibration is always required when the following components are
changed.
charging related components
ZOCUS (N130) and related components
UEME (D250) and related components
BSI related components
Energy management calibration
EM (Energy Management) calibration is performed to calibrate the setting (gain and off-
set) of AD converters in several channels (i.e. battery voltage, BSI, charger voltage,
charger current).
This is to get accurate conversion result of AD converter.
HW setup
“JBV-1 service concept” is needed.
An external power supply is needed.
The RH-51/52, RH-67/68 phone must be connected to JBV-1 (docking station) with DA-
18 (docking station adapter).
Connect SCB-3 (DC-DC cable) between JBV-1 and charger connector of phone for
charger channel calibration.
Supply 11-16V DC from an external power supply to JBV-1 to power up phone.
Phoenix SW setup
Start Phoenix service software.
Select FBUS connection.
Choose Main -> Choose product-> RH-51, -52, -67 or -68.
Choose Tuning -> Energy Management Calibration.