RF Troubleshooting
Company Confidential
Copyright © 2004 Nokia. All rights reserved
7A - 19
Issue 1
NOTE! ST_CDSP_RF_SUPPLY_TEST error code: 0x00, 0x00, 0x03, 0xBF, … means typically that
there is no VBAT_ASIC voltage coming to the Hinku RX ASIC at all or the ASIC is poorly
soldered to the PWB (All voltages that are somehow related to VBAT_ASIC are
causing errors).
Please, refer to chapter 2.11 “
Error Code Interpretation Examples”, if more information about
error code interpretation is needed.
2.10 TXC Data test (ST_TXC_DATA_TEST)
This self-test is used to check if the TXC-signal is coming correctly from Retu (N2200) to Vinku
(N7501).
Test covers: TxC power control signal, Retu (N2200), RFBUS, Vinku (N7501), VBAT_ASIC
Error code for this self-test is given in format:
• 0xyy, 0xzz, MeasResult1, MeasResult2, …
,where 0xyy, 0xzz part is the main part of the error code: 0xyyzz
Error
code
Bit mask Reason Actions
0x0001 ---------------1 TxC voltage too high with
minimum input.
Retu (or Vinku) faulty…Replace the
component.
0x0002 --------------1- TxC voltage too low with
maximum input.
3.1.1.1.1 “RF operating voltage
VBAT_ASIC?”
3.1.1.1.3 “Vinku (N7501) regulator
voltages VREG1, VREG2 ok?”
Check following step:
3.1.1.1.9 “
Is there TXC-signal coming to
Vinku ASIC (N7501)?”
Please, refer to chapter 2.11 “
Error Code Interpretation Examples”, if more information about
error code interpretation is needed.
2.11 Error Code Interpretation Examples
This chapter presents three different examples of RF error code interpretation.
2.11.1 Example 1
ST_CDSP_RX_PLL_PHASE_LOCK self test gives “Fatal” result with error code: 0x00, 0x04
This means that the total error code is 0x004 and if we look an error code table in Chapter 2.1
“
RX PLL phase lock self test” the meaning for the code is “Hinku PLL is not locked”.