User Guide

CCS Technical Documentation Service Tools
NPM-2NX
Issue 1 07/02 ãNokia Corporation Page 33
Mechanical Characteristics
Figure 12: MJF-1 main dimensions
Environmental Conditions
Temperature Conditions
Testing
Recommended Test Equipment
1 Power supply
2 Multimeter
Test Procedure
1 Make visual check that all mechanical parts are well placed and properly fixed
19 NC
20 NC
21 BTEMP BTEMP signal from phone
22 FBUS/RX FBUS RX signal from modular connector
23 MBUS MBUS signal from modular connector
24 VPP VPP signal from modular connector
25 GND_SENSE Battery gnd sense Used for regulator voltage feed-
back
Table 8: Mechanical characteristics
Unit
Dimensions (mm)
(W x H x D)
Weight (g) Material
MJF-1 71.5 x 36.8 x 119,6 150 ABS/PC, Cycoloy C1000F Color. 76701 Black
Table 9: Allowed ambient temperatures
Ambient Temperature (degrees Celcius)
Operating temperature +5…+35
Storage temperature -30…+60
Humidity RH Max. 90%