User Guide
NPM-2NX
Troubleshooting CCS Technical Documentation
Page 38 ãNokia Corporation Issue 1 07/02
Step 1. General checking
The fastest way to get overview of RX status is to measure RSSI (Received Signal
Strength Indicator) level. This can be done by using signal generator and Phoenix. Note
that this is useful only if the phone has been calibrated when it was OK and the mal-
function have occured after tunings.
1) Set signal generator frequency to 1960.06771 MHz and level to -80 dBm.
2) Select RSSI measurement UI in Phoenix (maintenance => GSM RSSI Meas).
3) Set Band to GSM1900 and Rx/Tx channel to 661
Check signal level
at RX band filter
Z802 input
Check components
around
lna
and
measure supply
voltages
Not OK
OK
Check signal level
at mix1_B input, L810
Replace RX band
filter Z802
Not OK
OK
Check signal level
at IF filter Z804
i
nput (133.2 MHz, R803)
Not OK
OK
Check signal level
at IF filter Z804
output (133.2
MHz), R804
Not OK
OK
Replace IF filter
Z804
Check signal level
at RX I/Q J808,
J809, J818, J819
Not OK
OK
Start synthesizer
troubleshooting
Replace Safari
N801
OK
Check UEM and
start
baseband
troubleshooting
Start synthesizer
troubleshooting
OK
Not OK
Check components
L815,
L814 etc.
Replace Safari N801
OK
Measure VR4 from L815
and L814 pads