Figure 12: Flashing, continued 2
Flash Programming Error Codes
The following characteristics apply to the information in Table 4.
Error codes can be seen from the test results or from Phoenix's flash-tool.
Underlined information means that the connection under consideration is being
used for the first time.
Table 4: Flash Programming Error Codes
Error Description Not Working Properly
C101 "The Phone does not set FbusTx line high after
the startup."
Vflash1
VBatt
BSI and FbusRX from prommer to UEME.
FbusTx from UPP->UEME->Prommer(SA0)
C102 "The Phone does not set FbusTx line low after
the line has been high. The Prommer generates
this error also when the Phone is not con-
nected to the Prommer."
PURX(also to Safari)
VR3
Rfclock(VCTCXO->Safari->UPP)
Mbus from Prommer->UEME-
>UPP(MbusRx)(SA0)
FbusTx from UPP->UEME->Prommer(SA1)
BSI and FbusRX from prommer to UEME.
CH1 = PURX
CH2 = MBUS
CH3 = FBUSTX
CH4 = FBUSRX
Measure points
Production test pattern
(J396)
FLASH_3
Data transfer has
started (Fbus_Rx)