User Guide

6255/6255i/6256/6256i (RM-19)
RF Description and Troubleshooting Nokia Customer Care
Page 52 ©2005 Nokia Corporation Company Confidential Issue 2 05/2005
Synthesizer Troubleshooting Setup
Use the following steps to troubleshoot the synthesizer using Phoenix:
1. On the Phone Control dialog box, click the LOCAL button in the Phone State
area to put the mobile terminal into Local Mode.
Figure 42: Phone Control dialog box
2. Select the following values on the RF Main Mode dialog box:.
Incorrect PLL Frequencies
Following are some possible causes for incorrect PLL frequencies:
Power supplies to PLL portion
Control line to VCO
Loop filter or resonator components missing or incorrectly installed
19.2MHz reference clock missing or low
Component failure (PLL IC, N7100, N7000, VCO, or VCTCXO)
Table 14: RF Main Mode Dialog Box Settings
Synthesizer Band Mode Channel
UHF
Cell Rx/Tx 384
PCS Rx/Tx 600
Rx VHF (one band is enough) Rx
Tx VHF Cell Rx/Tx 384
PCS Rx/Tx 600