The CDMA Control dialog box appears.
Figure 13: CDMA Control dialog box for Cell Tx troubleshooting
9. Select the following values:
State = Rho ON
Band = Cell
Radio Configuration = Mode 1: IS-95 Voice
Note: Do NOT select the Set default PDM values option
10. Click Execute.
11. Configure the spectrum analyzer using the following values:
Center Frequency = 836.52 MHz
Span = 100 MHz
Amplitude = 20 dBm
Attenuation = Auto
BW = Auto
Table 2: RF PDM Values
Description/Field Reference Value
AGC2 -250
AGC3 -387
Pout at RF connector +20dBm
Current 500-600mA
Do NOT select
this option