User Guide
6255/6255i/6256/6256i (RM-19)
RF Description and Troubleshooting Nokia Customer Care
Page 16 ©2005 Nokia Corporation Company Confidential Issue 2 05/2005
5. Click the LOCAL button in the Phone State area to put the mobile terminal into
Local Mode.
Figure 9: Phone Control dialog box
6. Open the Troubleshooting menu, point to AMPS, and click AMPS Control.
The AMPS Control dialog box appears.
Figure 10: AMPS Control dialog box
7. Click the Tx Control tab.
8. In the Set Channel field, type 384.
9. In the Power Level field, type 5.