User Guide

Nokia Customer Care RF Description and Troubleshooting
6235/6235i/6236i (RM-60)
Issue 1 04/2005 ©2005 Nokia Corporation Company Confidential Page 47
The level of 19.2MHz is also important because the D2800 is very sensitive and
can pick up a weak 19.2MHz clock. This can result in intermittent problems, such
as constant phone reset.
The synthesizers for 6235/6235i/6236i are:
Incorrect PLL Frequencies
Following are some possible causes for incorrect PLL frequencies:
Power supplies to PLL portion
Control line to VCO
Loop filter or resonator components missing or incorrectly installed
19.2MHz reference clock missing or low
Component failure (PLL IC, N7100, N7000, VCO, or VCTCXO)
Table 8: Synthesizers for 6235/6235i/6236i
Synthesizer Band Channel PLL
Dual Band UHF Cell and AMPS 1009.62 MHz at CH384 separate LMX2310 PLL IC
PCS 2088.10 MHz at CH600
Rx VHF Cell, AMPS and PCS 256.2 MHz inside N7100 IC
Tx UHF Cell and AMPS 3298.16~3395.88 MHz inside N7000 IC
PCS 3700.00~3819.90 MHz