User Guide

Nokia Customer Care RF Description and Troubleshooting
6235/6235i/6236i (RM-60)
Issue 1 04/2005 ©2005 Nokia Corporation Company Confidential Page 15
The CDMA Control dialog box appears.
Figure 11: CDMA Control dialog box for Cell Tx troubleshooting
9. Select the following values:
State = Rho ON
Band = Cell
Radio Configuration = Mode 1: IS-95 Voice
Note: Do NOT select the Set default PDM values option
10. Click Execute.
11. Configure the spectrum analyzer using the following values:
Center Frequency = 836.52 MHz
Span = 100 MHz
Amplitude = 20 dBm
Attenuation = Auto
BW = Auto
Table 2: RF PDM Values
Description/Field Reference Value
AGC1 0
AGC2 -512
PA Gain +114
Rx IF AGC 0
AFC 0
Pout +16dBm
Current 360mA
Do NOT select