User Guide

6235/6235i/6236i (RM-60)
RF Description and Troubleshooting
Page 12 ©2005 Nokia Corporation Company Confidential Issue 1 04/2005
The AMPS Control dialog box appears.
Figure 8: AMPS Control dialog box
7. Click the Tx Control tab.
8. In the Set Channel field, type 384.
9. In the Power Level field, type 5.
10. Select the Transmitter ON option, and click Execute.
11. Configure the spectrum analyzer using the following values:
Center Frequency = 836.52 MHz
Span = 100 MHz
Amplitude = 20 dBm
Attenuation = Auto
BW = Auto
Table 1: RF PDM Values at Power Level 5
Description/Field Reference Value
AGC1 -59
AGC2 -512
PA Gain -200
Rx IF AGC +179
AFC -12
Pout +17dBm
Current 370mA
Pout w/AAS-10 at Ant. Conn. -8 dBm