User Guide

RH-12/RH-28
Service Software Instructions CCS Technical Documentation
Page 68 Nokia Corporation Issue 1 02/04
GSM1900 PA high mode with EDGE off
Set Power Meter (or Spectrum analyzer) as required.
Repeat the same steps as for EGSM high and low mode above.
Tune base level and power levels 15,11 and 0 to target level.
When tuning values are correct, choose “Save & Continue”.
If all coefficients are within specified limits, tuning will continue on the GSM1900 PA
high mode with EDGE on.
Typical values:
Power level GSM1900 EDGE off
0 0.600 … 0.750
11 0.130 … 0.190
15 0.110 … 0.150
Base 0.090 … 0.130