User Guide
CCS Technical Documentation Service Software Instructions
RH-12/RH-28
Issue 1 02/04 Nokia Corporation Page 65
Repeat the same steps as for EGSM high and low mode above.
When EDGE is on, the tuning must be made for all power levels.
Tune base level and all power levels from 19 to 8 to target level.
When tuning values are correct, choose “Save & Continue”.
If all coefficients are within specified limits, tuning will continue on the EGSM900 PA
low mode with EDGE on.
Typical values:
EGSM900 PA low mode with EDGE on
This tuning step is not required for the RH-12 Product, phone will not react to any
controls.
Please choose “Save & Continue”.
Tuning will continue on the GSM1800 PA high mode with EDGE off.
GSM1800 PA high mode with EDGE off
Set Power Meter (or Spectrum analyzer) as required.
Repeat the same steps as for EGSM high and low mode above.
Tune base level and power levels 15,11 and 0 to target level.
Power level GSM900 EDGE on
8 0.500 … 0.650
9 0.400 … 0.550
10 0.350 … 0.500
11 0.320 … 0.470
12 0.300 … 0.440
13 0.280 … 0.400
14 0.250 … 0.350
15 0.230 … 0.330
16 0.210 … 0.310
17 0.200 … 0.300
18 0.190 … 0.290
19 0.180 … 0.280
Base 0.100 … 0.180