Service Tool Concept for RF Tunings
All RF tunings for RH-12* phones must be carried out in MJ-12 Module Jig.
Power to MJ-12 should be supplied from an external DC power supply, not FPS-8 prom-
mer.
MJ-12 input voltages:
Maximum + 16 VDC
Nominal input for RF tunings is +12 V DC
Remember cable attenuation when setting required RF levels.
RF tunings should be made in the same order as shown in this document, the order of the