User Guide
RH-12/RH-28
Service Software Instructions CCS Technical Documentation
Page 46 Nokia Corporation Issue 1 02/04
Select “Read from Phone” to show current values in the phone memory and to check
that the communication with the phone works.
Select “Calibrate” to run selected calibrations.
Limits for Energy Management Calibration:
Min Max
ADC gain 27000 28000
ADC offset -50 50
BSI gain 930 1100
VBAT gain 10000 11000
VBAT offset 2400 2600
VCHAR 58000 62000
ICHAR 3500 4600
If values shown are within limits, select “Save To Phone” to save values to phone.
NOTE! Only values of checked tunings (Battery size, Battery Temperature etc…) will be saved.
Close the “Energy Management Calibration” dialog to end tuning.