Environmental Specifications
Normal and extreme voltages
Following voltages are assumed as normal and extreme voltages for used battery:
Table 1: Normal and extreme voltages
1
ADC settings in the SW might shutdown the phone above this value.
2
During fast charging of an empty battery, the voltage might exceed this value. Voltages between
4.20 and 4.60 might appear for a short while.
Temperature conditions
• Operational temperature range (all specifications met within this range):
–5°C.. +55°C (stationary use)
• Functional temperature range (reduced performance):
–30°C.. +70°C
• Storage temperature range:
–30°C.. +85°C
Temperatures at –10°C, +25°C and +55°C are used for the cpk analysis.
The baseband module complies with the SPR4 Operating Conditions.
Voltage Voltage [V] Condition
General Conditions
Nominal voltage 3,700
Lower extreme voltage 3,145 1
Higher extreme voltage
(fast charging)
4,230 2
HW Shutdown Voltages
Vmstr+ 2,1 ± 0,1 Off to on
Vmstr- 1,9 ± 0,1 On to off
SW Shutdown Voltages
Sw shutdown 3,1 In call
Sw shutdown 3,2 In idle
Min Operating Voltage
Vcoff+ 3,1 ± 0,1 Off to on