User Guide
CCS Technical Documentation System Module
RH-27
Issue 1 11/2003 © 2003 Nokia Corporation Confidential Page 9
reasons, the phone software will shut the phone off if it senses a temperature of 38
o
C or
higher on BTEMP line.
Figure 2: Interconnection diagram
Supply Voltage Regulation
The UEM ASIC controls supply voltage regulation. There are six separate regulators used
by the baseband block. For a more detailed description about the regulator parameters,
see the document UEM ASIC Specification.
Charging
RH-27 baseband supports the NMP charger interface specified in the document Janette
Charger interface, SW control is specified in EM SW Specification, ISA EM Core SW
Project. The UEM ASIC controls charging, and external components are used to provide
EMC, reverse polarity, and transient protection of the charger input to the baseband
module. The charger connection is through the system connector interface. Both 2- and
3-wire type chargers are supported. The operation of the charging circuit has been spec-
ified to limit the power dissipation across the charge switch and to ensure safe operation
in all modes.
Table 3: BSI resistor values
Parameter Min Typ Max Unit Notes
Battery size indicator resistor BSI 75 kΩ Battery size indicator (BLD-3)
Tolerance “1%
NTC thermistor BTEMP 47
4000
kΩ
K
Battery temperature indica-
tor (NTC pulldown) 47kΩ“5%
@ 25
o
C
Beta value (B).
Tolerance “5%, 25
o
C / 85
o
C
Overcharge /
Overdischarge
protection
VBATT
BSI
BTEMP
EMC
Li-Ion