Figure 26 Battery pin order
The battery temperature can be measured from the main board.
Battery connector
The battery connector is a blade connector. It has three blades;
• BSI (Battery size indicator)
• GND (Ground)
• VBAT (Battery voltage)
The BSI line is used to recognize the battery capacity by a battery internal pull down resistor.
Figure 27 Battery connector
Charging
This phone is charged through the smaller Nokia standard interface (2.0 mm plug). The wider standard
charger (3.5 mm) can be used together the CA-44 charger adapter.
Figure 28 Wide (left) and small (right) charger plugs
Charging is controlled by energy management, and external components are needed to protect the baseband
module against EMC, reverse polarity and transient frequency deviation.
Charging a dead battery
Charging of a dead battery has to be carried out via one of the two approved NOKIA chargers (AC-6 and DC-6).
Charging via a PC is not allowed since this procedure is not including a current regulator (the battery can be
charged with a too high current level).