User Guide

NPE-3
Rf Troubleshooting PAMS Technical Documentation
3DJH 1RNLD0RELOH3KRQHV/WG ,VVXH
)DXOWILQGLQJFKDUWIRU3//6\QWKHVLVHU
,WLVLPSRUWDQWWRVD\WKDWSRZHUVXSSO\IRU9&7&;29;2LV2))RQO\LQ¨'HHS6OHHS
0RGH©DQGSRZHUVXSSO\IRU9&2*9FFLV2))LQ¨6OHHS0RGH©
,IWKHSKRQHJHWV¨GHDG©YHU\VKRUWWLPHDIWHUWKHSRZHULVWXUQHG21SRVVLEOHUHDVRQIRU
WKLVPLJKWEHWKDW0+]V\VWHPFORFNVLJQDOLVQRWFRPLQJWRWKH%%8VHWKHIROORZLQJ
FKDUWWRILQGWKHSUREOHP
From WinTesla chose:
Product
> Band > EGSM
Testing
> RF Controls >
Rx continuous > Ch 60
Spectrum Analyzer
VCO output ( G600 out)
3788 MHz
No
Yes
PLL block functional
Oscilloscope
VCTCXO Power Supply
(G602 Vcc)
2,7 V
Oscilloscope
VCTCXO output
(G602 out) 26 MHz,
approx. 0.8 Vpp
VCTCXO is dead
Oscilloscope
VCO Power Supply
(G600 Vcc) 2,7 V
Yes
No
Check CCONT,
Software?? Phone not in
function
Check CCONT,
Software?? Phone not
in function
Spectrum Analyzer
VCO output ( G600 out)
Some signal between 3
and 4 GHz
VCO is dead
Check HAGAR,
wrong writting to HAGAR
(SCLK,SDATA,SLE,
HAGARRESET)
Yes
No
No
Yes
Yes
No