CCS Technical Documentation NPL-3 Series Transceivers Service Software Instructions Issue 1 3/03 Copyright ãNokia. All rights reserved.
NPL-3 Company confidential Service Software Instructions CCS Technical Documentation [This page left intentionally blank] Page 2 Copyright ãNokia. All rights reserved.
Company confidential NPL-3 CCS Technical Documentation Quick Guide for Phoenix Service SW Installation ........................................................ 3 Phoenix Installation Steps in Brief ..............................................................................3 Phoenix Service SW....................................................................................................... 4 Before Installation ........................................................................................
NPL-3 Company confidential CCS Technical Documentation JBV-1 Flash Concept .................................................................................................82 Service Concept .........................................................................................................83 Parallel Flash concept ................................................................................................84 Page 2 Copyright ãNokia. All rights reserved.
Company confidential NPL-3 CCS Technical Documentation Quick Guide for Phoenix Service SW Installation Phoenix Installation Steps in Brief DCT-4 generation Test and Service Software is called “Phoenix” These are the basic steps to install the Phoenix • Install the Phoenix Service SW • Install the Data Package for Phoenix (product specific data and flash update package) • Manage connection settings (depends on the tools you are using) • Update FPS-8 SW (if you use FPS-8) • Activate FPS-8 • Upd
NPL-3 Company confidential CCS Technical Documentation Phoenix Service SW Before Installation • Check that a Dongle is attached to the parallel port of your computer. • Download the installation package (e.g. phoenix_service_sw_a7_2003_9_2_3.exe) to your computer (e.g. C:\TEMP) • Close all other programs • Run the application file (e.g. phoenix_service_sw_a7_2003_9_2_3.
Company confidential NPL-3 CCS Technical Documentation Startup Run the phoenix_service_sw_a7_2003_9_2_3.exe to start installation. When you choose “Next” the files needed for installation will be extracted. Kindly wait. If the setup files are already extracted (left in the file system from previous installation) following dialog appears. Always click "Yes to All" to overwrite the existing setup files. Issue 1 3/03 Copyright ãNokia. All rights reserved..
NPL-3 Company confidential CCS Technical Documentation Dongle Driver Installation and Version Check If there is no previously installed Dongle driver, installation will take place... If the Dongle driver is installed and it is older than the latest supported version, the latest version will be installed when you choose “Yes”. The latest version is always included in the latest Phoenix installation package. PC needs to be rebooted before installation can continue. Click "Yes" to reboot the PC.
Company confidential NPL-3 CCS Technical Documentation First Time Installation of Phoenix After Dongle driver installation / update (if needed) installation continues from this step. Click "Next" in Welcome dialog to continue. Choose the destination folder, it is recommended to use the default folder C:\ProgramFiles\Nokia\Phoenix. Choose “Next” to continue. You may choose another location by selecting “Browse” (not recommended) Setup copies the components, please wait. Issue 1 3/03 Copyright ãNokia.
NPL-3 Company confidential CCS Technical Documentation Progress of the setup is shown. Please wait… If restarting of your computer is needed the Install Shield Wizard will tell you about it. Select "Yes..." to reboot the PC immediatelly and "No..." to reboot the PC manually. Note that Phoenix doesn't work, if components are not registered. Click "Finish" to continue. After the reboot components are registered and Phoenix is ready for use. Page 8 Copyright ãNokia. All rights reserved.
Company confidential NPL-3 CCS Technical Documentation If reboot is not needed components are registered after copying them. If restarting of your computer is not needed, Click "Finish" to exit the setup. Phoenix is now ready for use.
NPL-3 Company confidential CCS Technical Documentation Update Installation of Phoenix If you already have the Phoenix Service SW installed on your computer, sooner or later there will be need to update it when new versions are released. Please note that very often the Phoenix Service SW and the Phone Specific Data Package for Phoenix come in pairs, meaning that certain version of Phoenix can only be used with certain version of Data Package. Always use the latest available versions of both.
Company confidential NPL-3 CCS Technical Documentation How to Uninstall Phoenix Uninstallation can be done manually from Windows Control Panel - Add / Remove Programs. Choose “Phoenix Service Software” and click "Add/Remove". Choose “OK” to uninstall Progress of the uninstallation is shown. Issue 1 3/03 Copyright ãNokia. All rights reserved..
NPL-3 Company confidential CCS Technical Documentation You may have to reboot the PC after uninstallation. If restarting is not needed, the following dialog will appear: Note! If you have different product packages installed, components are uninstalled only if they are not included in other product packages. Page 12 Copyright ãNokia. All rights reserved.
Company confidential NPL-3 CCS Technical Documentation Data Package for Phoenix (Product Specific) Before installation Product Data Package contains all product specific data to make the Phoenix Service Software and tools usable with a certain phone model. It also includes the latest version of flash update package for FLS-4S* and FPS-8* • Check that the Dongle is attached to the parallel port of your computer. • Install Phoenix Service SW • Download the installation package (e.g. npl-3_dp_v1.0_sw3.
NPL-3 Company confidential CCS Technical Documentation Installation of Phoenix Data Package (Product Specific) Run the npl-3_dp_v1.0_sw3.02.exe to start installation. When you choose “Next” the files needed for installation will be extracted. Please wait… Choose “Next” to continue. From this view you can see the contents of the Data Package. Read the text carefully. Page 14 Copyright ãNokia. All rights reserved.
Company confidential NPL-3 CCS Technical Documentation There should be information about the Phoenix version needed with this data package. Choose “Next”. Confirm location and choose “Next” to continue. Install Shield checks where the Phoenix application is installed and the directory is shown. Choose “Next” to continue. Phone model specific files will be installed... please wait. Issue 1 3/03 Copyright ãNokia. All rights reserved..
NPL-3 Company confidential CCS Technical Documentation Choose “Finish” to complete installation. You now have all phone model specific files installed in your Phoenix Service SW. Page 16 Copyright ãNokia. All rights reserved.
Company confidential NPL-3 CCS Technical Documentation How to Uninstall Data Package Uninstallation can also be done manually from Windows Control Panel / Add / Remove Programs/ “NPL-3 Phone Data Package”. If you try to install the same version of Phoenix Data Package that you already have, you are asked if you want to uninstall the version you have on your PC. Answer “OK” to uninstall, “Cancel” if you don’t want to uninstall. Older versions of data packages do not need to be uninstalled.
NPL-3 Company confidential CCS Technical Documentation How to Manage Connections Start Phoenix Service SW and Login. Choose “Manage Connections” From “File” – Menu Existing connections can be selected, edited, deleted and new ones created by using this dialog. A connection can be created either manually or by using a Connection Wizard. To add new connection, choose “Add” and select if you want to create it manually or by using the Wizard. Choose “Next” to continue. Page 18 Copyright ãNokia.
Company confidential NPL-3 CCS Technical Documentation In the next dialogs you will be asked to select some settings for the connection Manual Settings A) For FLS-4S POS Flash Device choose following connection settings: Media: FBUS COM Port: Virtual COM Port used by FLS-4S.
NPL-3 Company confidential CCS Technical Documentation Activate the connection you want to use by clicking it and use up/down arrows to move it on top of the list. Choose “Apply”. The connection is now selected and can be used after closing the “Manage Connections” window. Selected connection will be shown on the right hand bottom corner of the screen. To use the selected connection, connect the phone to Phoenix with correct service tools, make sure that it is switched on and select “Scan Product”.
Company confidential NPL-3 CCS Technical Documentation How to Update Flash Support Files for FPS-8* and FLS-4S* Before Installation • Install Phoenix Service SW and Phoenix data package. • Install the phone model Specific Datapackage for Phoenix • The flash support files are delivered in the same installation package with Phoenix data package. • Normally it is enough to install the data package only before updating the FPS8.
NPL-3 Company confidential CCS Technical Documentation Choose “Next” to continue installation It is highly recommended to install the files to the default destination folder C:\Program Files\Nokia\Phoenix. Choose “Next” to continue. You may choose another location by selecting “Browse” (not recommended). Page 22 Copyright ãNokia. All rights reserved.
Company confidential NPL-3 CCS Technical Documentation Installation continues… Choose “Finish” to complete procedure. • FLS-4S can be used right after Flash Update Package is installed. • FPS-8* must be updated by using Phoenix! Issue 1 3/03 Copyright ãNokia. All rights reserved..
NPL-3 Company confidential CCS Technical Documentation How to Update The FPS-8* Flash Prommer SW Start Phoenix Service Software Select”FPS-8 / FPS-8C maintenance” from”Flashing” menu. When new FPS-8 flash update package is installed to computer you will be asked to update the files to your FPS-8 Prommer. Select”Yes” to update files.. 0 02 Update procedure takes a couple of minutes. Page 24 Copyright ãNokia. All rights reserved.
Company confidential NPL-3 CCS Technical Documentation FPS-8 sw can also be updated by pressing”Update” button and selecting appropriate fps8upd.ini file under C:\Program Files\Nokia\Phoenix\Flash - directory All files can be loaded separately to FPS-8. To do this, just press right mouse button in Flash box files” window and select file type to be loaded. More information and help can be found from the “Help” dialog. Issue 1 3/03 Copyright ãNokia. All rights reserved..
NPL-3 Company confidential CCS Technical Documentation FPS-8 Activation and Deactivation • Before the FPS-8 can be successfully used for phone programming, it must be first activated. • If there is a need to send FPS-8 box to somewhere e.g. for repair, box must be first deactivated. Activation Before FPS-8 can be successfully used for phone programming, it must be first activated. Fill in first “FPS-8 activation request” sheet, in the FPS-8 sales package and follow the instructions in the sheet.
Company confidential NPL-3 CCS Technical Documentation The activation file you saved to C:\ProgramFiles\Nokia\Phoenix\BoxActivation - directory will be shown (e.g. 00000.in), check that it is correct. Box will be activated when you choose “Open”. Turn FPS-8 power off and on to complete activation. Issue 1 3/03 Copyright ãNokia. All rights reserved..
NPL-3 Company confidential CCS Technical Documentation Deactivation Start Phoenix Service Software. Select ”FPS-8 / FPS-8C maintenance” from ”Flashing” menu. Select “Deactivate” from the “FPS8/8C Maintenance” – UI. Confirm Deactivation by choosing “Yes”, Box will be deactivated. Turn FPS-8 power off and on to complete deactivation. Page 28 Copyright ãNokia. All rights reserved.
Company confidential NPL-3 CCS Technical Documentation JBV-1 Docking Station SW The JBV-1 Docking Station is a common tool for all DCT-4 generation products. In order to make the JBV-1 usable with different phone models, a phone specific Docking Station Adapter is used for different service functions. The JBV-1 Docking Station contains Software (Firmware) which can be updated.
NPL-3 Company confidential CCS Technical Documentation Installing SW Needed for the JBV-1 SW Update Note: DO NOT CONNECT THE USB CABLE / JBV-1 TO YOUR COMPUTER YET! Run Jbv1_update.zip file and start SW Installation by double clicking Setup.exe. Files needed for JBV-1 Package setup Program will be extracted. Installation begins, please read the information shown and Choose “Next” to continue.
Company confidential NPL-3 CCS Technical Documentation “Next” to continue. Select “Full” Installation and choose “Next” to continue Program Folder will be created. Choose “Next” to continue, Software files will be Issue 1 3/03 Copyright ãNokia. All rights reserved..
NPL-3 Company confidential CCS Technical Documentation installed. After successful installation, choose “Finish” to complete. NOW YOU CAN CONNECT THE USB CABLE / JBV-1 TO YOUR COMPUTER! Connect power to JBV-1 (11-16V DC) from external power supply, then connect USB Page 32 Copyright ãNokia. All rights reserved.
Company confidential NPL-3 CCS Technical Documentation Cable between JBV-1 USB connector and PC. Windows will detect connected USB cable and detect drivers for new HW. Follow the instructions and allow Windows to search and install the best drivers available. After this procedure the actual JBV-1 SW update can begin. Issue 1 3/03 Copyright ãNokia. All rights reserved..
NPL-3 Company confidential CCS Technical Documentation Updating the JBV-1 Docking Station Software Go to folder C:\Program Files\Nokia\ JBV-1 SW Package\ FIRMWARE UPDATE and start JBV-1 Update SW by double clicking fwup.exe. JBV-1 Firmware update starts and shows current status of the JBV-1 connected. If firmware version read from your JBV-1 is not the latest one available, it needs to be updated by choosing “Update Firmware”. Choose file JBV1v11.
Company confidential NPL-3 CCS Technical Documentation software of your JBV-1 docking station and it is ready for use. Issue 1 3/03 Copyright ãNokia. All rights reserved..
NPL-3 Company confidential CCS Technical Documentation [This page left intentionally blank] Page 36 Copyright ãNokia. All rights reserved.
NPL-3 CCS Technical Documentation Receiver tuning: Quick Guide for Tuning With Phoenix General remarks RF tunings must be performed in the same order as shown in this document. The order of the corresponding menu items in the Service SW may be different. If baseband tunings are needed, they should be completed before the RF tunings. Avoid unnecessary tuning – factory-tuning values are always the most accurate ones. NOTE! RF tunings need to be done ONLY if any RF block component is replaced.
NPL-3 CCS Technical Documentation Service Tool Concept for RF Tuning Operations NOTE! RF tunings need to be done ONLY if any RF block component is replaced. • All RF tuning operations must be carried out in the MJS-38 Module Jig! • Power to MJS-38 must be supplied from an external DC power supply, not FPS-8 prommer • MJS-38 input voltages: Maximum + 5 VDC Nominal input for RF tunings is +4.
NPL-3 CCS Technical Documentation Item: Service accessory: Type: 6 Service SW CD-ROM Product code: Autotuning Autotune feature is designed to align product’s RF part easier and faster. By this autotune component the product is tuned automatically. The user only needs to press ‘Tune’ and the product’s RF is tuned and results are shown to the user. Component controls all the needed RF equipment (RF generator and TX measuring device) except voltage supplier.
NPL-3 CCS Technical Documentation Figure 4: Autotune menu - RX/TX menu Set Loss Figure 5: Set Loss menu This is the component for saving RF-losses (of cables and jigs) to file. These loss values are needed when you tune the phone with Phoenix (using Auto-Tune component). When you measure the losses you have to be very careful, because these values affect directly how well the phone is tuned. NOTE! This component is only for Auto-Tune uses. Page 40 Copyright ãNokia. All rights reserved.
NPL-3 CCS Technical Documentation Figure 6: Loss values Environment Hardware requirements: PC with Windows 98/2000/NT Power supply Product specific module jig RF-splitter and -cables RF equipment (only one of each is needed) Tx: Agilent E4406 (VSA series transmitter tester) Agilent E4445 (PSA series transmitter tester) Rohde&Schwarz, FSE-family of Signal Analyzers Rohde&Schwarz, FSIQ-family of Signal Analyzers Rx: Agilent ESG family of RF Signal Generators Rohde&Schwarz, SME-family of Signal Generators Is
NPL-3 CCS Technical Documentation Figure 7: Setup environment GPIB addresses are not defined. Component finds the addresses and uses them automatically. If several TX tuning devices are connected, this component uses Agilent (VSA or PSA). In RX side, Agilent has highest priority. Protection Components are protected by PKD-1CS, PKD-1NS, PKD-1 and PKD-1P dongles using standard TSS protection procedure.
NPL-3 CCS Technical Documentation Uncheck “Save to Phone “ if you don´t want the values to be saved to phone (eg testing)! Press "Tune" to start the tuning Tuning values must be 0…31 If values shown are within limits, choose “Stop” Close the “RX Channel Select Filter Calibration“-dialog to end tuning Close the Rx Channel select filter calibration dialog, the values are saved to phone Issue 1 3/03 Copyright ãNokia. All rights reserved..
NPL-3 CCS Technical Documentation RX Calibration RF generator needed. This tuning performs RX Calibration. Must be done separately on every band! Calibration is automatically performed at GSM850, then at GSM1800 and finally at GSM1900 band. If tuning is successful, it continues in the next band. AFC tuning is done while GSM850 band RX Calibration is performed. Remember to take jig and cable attenuations into account! Select Tuning => Rx calibration Press “Calibrate"´to start tuning.
NPL-3 CCS Technical Documentation Set RF generator to required frequency => OK Tuning values and ADC readings are shown. Typical values and limits in GSM850 RX Calibration: GSM850 Typical value Low limit High limit Afc value: -90 -350 350 Afc slope: 270 150 350 Rssi 0: 65.09375 58 68 Rssi 1: 71.09375 64 74 Rssi 2: 76.90625 70 80 Rssi 3: 82.90625 76 86 Rssi 4: 88.90625 82 92 Rssi 5: 93.71875 88 98 Rssi 6: 99.71875 94 104 Rssi 7: 105.53125 100 110 Rssi 8: 111.
NPL-3 CCS Technical Documentation Tuning values and ADC readings are shown. Typical values and limits in (GSM1800) RX Calibration Page 46 GSM1800 Typical value Low limit High limit Rssi 0: 62.40625 58 68 Rssi 1: 68.40625 64 74 Rssi 2: 74.265625 70 80 Rssi 3: 80.265625 76 86 Rssi 4: 86.265625 82 92 Rssi 5: 91.859375 88 98 Rssi 6: 97.859375 94 104 Rssi 7: 103.71875 100 110 Rssi 8: 109.71875 106 116 Rssi 9: 115.71875 112 122 Rssi 10: 121.
NPL-3 CCS Technical Documentation Set the RF generator to required GSM1900 frequency => OK Tuning values and ADC readings are shown. Typical values and limits in (GSM1900) RX Calibration GSM1900 Typical value Low limit High limit Rssi 0: 66.25 61 71 Rssi 1: 72.25 67 77 Rssi 2: 78.09375 73 83 Rssi 3: 84.09375 79 89 Rssi 4: 90.09375 85 95 Rssi 5: 93.25 88 98 Rssi 6: 99.25 94 104 Rssi 7: 105.09375 100 110 Rssi 8: 111.09375 106 116 Rssi 9: 117.
NPL-3 CCS Technical Documentation RX Band Filter Response Compensation RF generator needed.
NPL-3 CCS Technical Documentation Select "Manual tuning" and tuning starts. You are asked to supply 9 different RF frequencies to the phone. The tuning begins from GSM850 band and continues the same way for GSM 1800 and GSM1900 bands Set the first required frequency and level => OK Set the 2nd required frequency and level => OK Issue 1 3/03 Copyright ãNokia. All rights reserved..
NPL-3 CCS Technical Documentation Set the 3rd required frequency and level => OK Set the 4th required frequency and level => OK Set the 5th required frequency and level => OK Set the 6th required frequency and level => OK Set the 7th required frequency and level => OK Page 50 Copyright ãNokia. All rights reserved.
NPL-3 CCS Technical Documentation Set the the 8th required frequency and level => OK Set 9th required frequency and level => OK Typical values and limits in Rx Band Filter Response Compensation GSM850: Input Channel Frequency (MHz) Low limit (dB) High limit (dB) 118 863.26771 -10 3.5 128 869.26771 -3.5 3.5 140 871.66771 -3.5 3.5 172 878.06771 -3.5 3.5 190 881.66771 -3.5 3.5 217 887.06771 -3.5 3.5 241 891.86771 -3.5 3.5 251 893.86771 -3.5 3.5 261 895.86771 -10 3.
NPL-3 CCS Technical Documentation Continue tuning from GSM1800. Choose the correct band from the dropdown menu. Repeat the same steps as for the GSM850 band above. Typical values and limits in Rx Band Filter Response Compensation GSM1800: Channel 497 512 535 606 700 791 870 885 908 Input Frequency (MHz) Low limit (dB) High limit (dB) 1802.26771 -10 3.5 1805.26771 -3.5 3.5 1809.86771 -3.5 3.5 1824.06771 -3.5 3.5 1842.86771 -3.5 3.5 1861.06771 -3.5 3.5 1876.86771 -3.5 3.5 1879.86771 -3.5 3.5 1884.
NPL-3 CCS Technical Documentation Typical values and limits in Rx Band Filter Response Compensation GSM1900: Input Channel Frequency (MHz) Low limit (dB) High limit (dB) 496 1927.06771 -10 3.5 512 1930.26771 -3.5 3.5 537 1935.26771 -3.5 3.5 586 1945.06771 -3.5 3.5 661 1960.06771 -3.5 3.5 736 1975.06771 -3.5 3.5 794 1986.66771 -3.5 3.5 810 1989.86771 -3.5 3.5 835 1994.86771 -10 3.5 Choose "Stop, write to PM area". If the values shown are within limits, choose “Yes” to save values to the phone.
NPL-3 CCS Technical Documentation Press “Start” to begin tuning. Adjust signal generator accordingly and press “OK” to tune. When tuning is finished, press “Save & Continue”. Tuning continues automatically at GSM1800 band. Page 54 Copyright ãNokia. All rights reserved.
NPL-3 CCS Technical Documentation Adjust signal generator accordingly and press “OK” to tune. When tuning is finished, press “Save & Continue”. Tuning continues automatically at GSM1900 band. Adjust signal generator accordingly and press “OK” to tune. Issue 1 3/03 Copyright ãNokia. All rights reserved..
NPL-3 CCS Technical Documentation When tuning is finished, press “Save & Continue”. If the Rx Am Suppression tuning was completed successfully, press “OK” to stop tuning. Close the Rx Am Suppression window. Page 56 Copyright ãNokia. All rights reserved.
NPL-3 CCS Technical Documentation RX DTOS balance calibration Extra equipment / external RF signal not needed Must be done separately on each band! Start RX Calibration for GSM850, then continue at the GSM1800 band and finally at the GSM1900 band. This Calibration is used for calibrating DSP control words values. Select Tuning => Rx DtoS Balance Calibration NOTE! No RF-input is allowed to feed when calibrating Choose “OK” and “Start”, tuning begins automatically at the GSM850 band.
NPL-3 CCS Technical Documentation Select “OK” to start tuning with values already saved to the phone Press “Calibrate” If values shown are within limits, Select “Stop” choose “Yes” to save values to the phone Continue tuning from GSM1800. Choose the correct band from the dropdown menu. Repeat the same steps as for the GSM850 band. If values shown are within limits, choose “Yes” to save values to the phone. Page 58 Copyright ãNokia. All rights reserved.
NPL-3 CCS Technical Documentation Continue tuning from GSM1900. Choose the correct band from the dropdown menu. Repeat the same steps as for the GSM850 and GSM1800 bands. If values shown are within limits, choose “Yes” to save values to the phone. Close the RX DtoS Balance Calibration dialog to end Receiver tuning. Issue 1 3/03 Copyright ãNokia. All rights reserved..
NPL-3 CCS Technical Documentation Transmitter Manual Tuning TX Power Level Tuning Power meter or spectrum analyzer needed. With Tx Power Level Tuning, the coefficients are adjusted for each power level. Start Power Level tuning at GSM850/EDGE, then continue at GSM1800/EDGE band and finally at the GSM1900/EDGE band. Tuning => Tx power level tuning Select “Start”, tuning begins at the GSM850 band Set up spectrum analyzer accordingly. Page 60 Copyright ãNokia. All rights reserved.
NPL-3 CCS Technical Documentation Remember to take the jig and cable attenuations into account! The coefficient table lists the power level, coefficient, target dBm and DAC value for each power level. The tuned power level can be chosen by using up and down arrows or mouse. The current power level is shown with inverse colors. The tuning value can be adjusted with “-“ and “+” keys. Tune Base level and power levels 19, 15 and 5 to target level. Issue 1 3/03 Copyright ãNokia. All rights reserved..
NPL-3 CCS Technical Documentation Press "Calculate coefficients". Typical values: GSM850 Power level DAC Value 5 0.670…0.850 15 0.210…0.240 19 0.170…0.200 Base 0.140…0.170 Press “Save & Continue”. Tuning values will be calculated and saved to phone’s memory. Tuning continues at EDGE850. Set up spectrum analyzer accordingly. Page 62 Copyright ãNokia. All rights reserved.
NPL-3 CCS Technical Documentation Press “OK” and start tuning. Tune all power levels to target level. Note! Target for EDGE Base level is -15dBm. Press “Save & Continue” to save the tuning values to phone’s memory. Continue tuning at GSM1800 band Set up spectrum analyzer accordingly. Remember to take the jig and cable attenuations into account! Issue 1 3/03 Copyright ãNokia. All rights reserved..
NPL-3 CCS Technical Documentation Press “OK” and start tuning. Tune Base level and power levels 15,11 and 0 to target level. Typical values: GSM1800 Power level DAC Value 0 0.580…0.700 11 0.210...0.240 15 0.180…0.210 Base 0.135…0.165 Press “Save & Continue”. Tuning values will be calculated and saved to phone’s memory. Page 64 Copyright ãNokia. All rights reserved.
NPL-3 CCS Technical Documentation Tuning continues at EDGE1800. Set up spectrum analyzer accordingly. Press “OK” and start tuning. Tune all power levels to target level. Note! Target for EDGE Base level is -15dBm. Press “Save & Continue” to save the tuning values to phone’s memory. Issue 1 3/03 Copyright ãNokia. All rights reserved..
NPL-3 CCS Technical Documentation Continue tuning at GSM1900 band Set up spectrum analyzer accordingly. Remember to take the jig and cable attenuations into account! Press “OK” and start tuning. Tune Base level and power levels 15, 11 and 0 to target level. Page 66 Copyright ãNokia. All rights reserved.
NPL-3 CCS Technical Documentation Typical values: GSM1900 Power level PA high mode 0 0.580…0.700 11 0.210…0.240 15 0.180…0.210 Base 0.150…0.165 Press “Save & Continue”. Tuning values will be calculated and saved to phone’s memory Tuning continues at EDGE1900. Set up spectrum analyzer accordingly. Issue 1 3/03 Copyright ãNokia. All rights reserved..
NPL-3 CCS Technical Documentation Press “OK” and start tuning. Tune all power levels to target level. Note! Target for EDGE Base level is -15dBm. Press “Save & Continue” to save the tuning values to phone’s memory. TX Power Level Tuning is now completed. Page 68 Copyright ãNokia. All rights reserved.
NPL-3 CCS Technical Documentation TX I/Q Tuning Spectrum analyzer needed. Tx IQ Tuning allows changing the Tx I DC Offset, Tx Q DC Offset, Amplitude difference and Phase difference. Must be done separately on all bands! Select Tuning => Tx_IQTuning Tx IQ Tuning window will open. Press “Start” and tuning will begin at GSM850 band. Issue 1 3/03 Copyright ãNokia. All rights reserved..
NPL-3 CCS Technical Documentation Adjust spectrum analyzer accordingly. Press “OK” and start tuning. Tuning is done by setting each of the sliders to desired value. The order of tuning should be the same as the order of the sliders, that is, the Tx I DC Offset is tuned first and Phase difference is tuned last. Use <= , =>, PgUp or PgDn keys. Tune LO leakage to minimum with TXI/TXQ DC Offset control (f0 on spectrum analyzer screen).
NPL-3 CCS Technical Documentation 67.71kHz on spectrum analyzer screen). LO leakage Unwanted sideband LO leakage and unwanted sideband are tuned to minimum Tuning limits are the same for all bands (GSM/EDGE850, GSM/EDGE1800 and GSM/ EDGE1900): Tuning limits: Issue 1 3/03 I DC Offset -6…+6 Q DC Offset -6…+6 Copyright ãNokia. All rights reserved..
NPL-3 CCS Technical Documentation Tuning limits: Amplitude difference -1…+1 Phase difference - 80°…100° When the IQ spectrum is balanced, “Save & Continue” to EDGE850 TX IQ tuning. Spectrum analyzer settings are the same as for GSM850 IQ tuning. NOTE! In EDGE-mode, the unwanted sideband is located at 50.8kHz from f0. 50.8kHz When the IQ spectrum is balanced, press “Save & Continue”. Continue tuning at GSM/EDGE1800 band Adjust spectrum analyzer accordingly. Page 72 Copyright ãNokia.
NPL-3 CCS Technical Documentation Both GSM and EDGE 1800 use the same settings. Continue tuning at GSM/EDGE1900 band Adjust spectrum analyzer accordingly. Both GSM and EDGE 1900 use the same settings. When GSM and EDGE 1900 are tuned, press “Save & Continue”. Press “OK” and the TX IQ Tuning is completed. Issue 1 3/03 Copyright ãNokia. All rights reserved..
NPL-3 CCS Technical Documentation Service Tool Concept For Baseband Tuning Operations EM calibrations should be carried out in JBV-1 Docking Station equipped with DA-19 Docking Station Adapter. Note: RF tunings must be carried out in MJS-38 module jig, JBV-1. Power to JBV-1 should be supplied from an external DC power supply, not FPS-8 prommer. JBV-1 input voltages: Maximum +16 VDC Nominal input for RF tunings is +12 V DC. Page 74 Copyright ãNokia. All rights reserved.
NPL-3 CCS Technical Documentation Service Concept for NPL-3* Baseband tunings 7 8 4 6 3 5 2 1 Item Accessory type Service Accessory Product code 1 JBV-1 Docking Station 0770298 2 DA-19 Docking Station adapter 0770674 3 SCB-3 DC-DC Cable 0730114 5 PCS-1 DC power cable 0730012 6 DAU-9S Service FBUS cable 0730108 7 PKD-1 Software protection key 0750018 8 Service SW CD-ROM Issue 1 3/03 Copyright ãNokia. All rights reserved..
NPL-3 CCS Technical Documentation Baseband Tuning operations Energy Management Tuning External power supply needed. Energy Management (EM) Calibration is used for calibrating Battery and Charger settings of the phone. Preparation for EM Calibration: - Connect the DC Cable SCB-3 between JBV-1 and Vin of the Phone for Charger calibration. - Connect 12…15 V from the Power Supply to JBV-1. - NOTE! Check that the connection is F-BUS (does not work with M-BUS). Select Tuning => Energy Management Calibration.
NPL-3 CCS Technical Documentation Select “Calibrate” to run the selected calibrations. Limits for Energy Management Calibration: Parameter Min.
NPL-3 CCS Technical Documentation LCD Contrast Tuning Extra equipment not needed. This function is used to calibrate the LCD Contrast. Must be done when LCD module is changed and there is considerable difference in the contrast. Select Testing => Display Tune Move the sliders to reach good LCD contrast. Close the ”Display tune” dialog to end tuning. Page 78 Copyright ãNokia. All rights reserved.
Company confidential NPL-3 CCS Technical Documentation Flashing Setup Instructions POS (Point of Sale) Flash Concept 4 5 2 3 1 Figure 1: POS flash Item Type Description Code 1 FLA-27 Point Of sales flash loading adapter 0770492 2 XCS-1 Service cable 0730218 3 ACF-8 AC Charger 0680032 4 FLS-4S FLS-4S sales package E&A 0080541 FLS-4S, FLS-4S sales package APAC 0080542 FLS-4S, FLS-4S sales package US 0080543 5 Issue 1 3/03 Service SW CD-ROM Copyright ãNokia.
NPL-3 Company confidential CCS Technical Documentation Flash Concept with Flashing adapter 7 9 8 6 5 4 2 3 1 Figure 2: Flash comcept with flashing adapter Item Type Description Code 1 FLA-27 Point of sales flash loading adapter 0770326 2 FLC-2 Power cable, incl in FLA-27 sales package 0730185 3 XCS-4 Modular cable 0730178 4 FPS-8 Flash prommer box with 2x SF12 SRAM 0080321 and 0080346 Centronics (printer) cable, incl in FPS-8 sales package 0730029 5 6 AXS-4 RS-232 (D9-D9) c
Company confidential NPL-3 CCS Technical Documentation Module Jig Concept 5 6 2 4 1 3 Figure 3: Module jig concept Item Type Description Code 1 MJS-38 Module jig 0770416 2 PCS-1 DC power cable 0730012 3 XRF-1 RF antenna cable 0730085 4 DAU-9S Service FBUS cable 0730108 5 PKD-1 Software protection key 0750018 6 Issue 1 3/03 Service SW CD-ROM Copyright ãNokia. All rights reserved..
NPL-3 Company confidential CCS Technical Documentation JBV-1 Flash Concept 7 9 8 6 4 5 3 2 1 Flash2_wolfgang VP 03-02-26 Figure 4: JBV-1 Flash concept Item Type Description Code 1 JBV-1 Docking station 0770298 2 PCS-1 DC power cable 0730012 3 XCS-4 Modular cable 0730178 4 FPS-8 Flash prommer box 0080321 5 Printer cable Incl. in FPS-8 sales pack 0730029 6 AXS-4 D9 – D9 cable, incl.
Company confidential NPL-3 CCS Technical Documentation Service Concept 7 8 4 6 3 5 2 1 Figure 5: Service Concept Item: Service accessory: Type: Product code: 1 Docking station JBV-1 0770298 2 Docking station adapter DA-19 0770674 3 DC-DC cable SCB-3 0730114 4 RF antenna cable XRF-1 0730085 5 DC power cable PCS-1 0730012 6 Service FBUS cable DAU-9S 0730108 7 Software protection key PKD-1 0750018 8 Service SW CD-ROM Issue 1 3/03 Copyright ãNokia.
NPL-3 Company confidential CCS Technical Documentation Parallel Flash concept Test consept wolfgang VP 03-02-26 Figure 6: Parallel flash concept Item Type Description Code 1 DA-19 Docking station adapter 0770674 2 JBV-1 Docking station 0770298 3 XCS-4 Modular cable 0730178 4 PCS-1 DC power cable 0730012 7 AXS-4 D9 – D9 cable, incl. in FPS-8C sales pack 0730090 8 Printer cable Incl.