PAMS Technical Documentation NSE/B/C/K/M/W–1/3 Series Transceivers Service Tools Original 10/98
NSE/B/C/K/M/W–1/3 PAMS Technical Documentation Service Tools AMENDMENT RECORD SHEET Amendment Date Number 01 Page 2 04/98 10/98 Inserted By Comments Original J. Rantala NSM–1 phone type and CAH–1 added. Repaginated.
NSE/B/C/K/M/W–1/3 PAMS Technical Documentation Service Tools CONTENTS Page No Battery Adapter BDC–3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of BDC–3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Service Battery BBD–3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Code . . .
NSE/B/C/K/M/W–1/3 Service Tools PAMS Technical Documentation Product Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of AXS–5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DC Charging Cable PCC–1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of PCC–1 . . . . . . . . . . . .
NSE/B/C/K/M/W–1/3 PAMS Technical Documentation Service Tools Battery Adapter BDC–3 The Battery Adapter BDC–3 is used along with an external battery capacity meter to check battery capacity. Note that Li–ion batteries have an internal protection circuit to prevent deep discharge.
NSE/B/C/K/M/W–1/3 Service Tools PAMS Technical Documentation Service Battery BBD–3 The Service Battery BBD–3 is used in place of the phone’s normal battery during service, to supply a controlled operating voltage to the phone for current and charger calibration, and is also required when flashing the phone. Note that the cable SCB–3 (0730114) is also required for charger calibration.
NSE/B/C/K/M/W–1/3 PAMS Technical Documentation Service Tools Light Module Jig JBT–1 The Light Module Jig JBT–1 is used for component level repair of the system/RF module. * Product Code Light Module Jig JBT–1: 0770109 View of JBT–1 *) Connect the External antenna cable XRC–1B, service Cable SCH–5, and the DC Cable PCS–1 to the JBT–1 jig. The service cable SCH–5 can be replaced by the DAU–9P cable. Note: Original 10/98 The nominal supply voltage for JBT–1 is +3.6 V.
NSE/B/C/K/M/W–1/3 PAMS Technical Documentation Service Tools Module Jig JBS–19 The Module Jig JBS–19 is used for repair of both system/RF and UIF modules. * Product Code Light Module Jig JBS–19: 0770098 View of JBS–19 *) Connect the External antenna cable XRC–1B, service Cable SCH–5, and the DC Cable PCS–1 to the JBS–19 jig. The service cable SCH–5 can be replaced by the DAU–9P cable. Note: The nominal supply voltage for JBS–19 is +3.6 V. The supply voltage must not exceed +4.0 V.
NSE/B/C/K/M/W–1/3 PAMS Technical Documentation Service Tools Flash Loading Adapter FLA–5 (Sales Pack) The Flash Loading Adapter FLA–5 is used with the Service Battery BBD–3 and Service Cable SCH–5. Power is supplied to FLA–5 from the Flash Security Box TDF–4 via the DC cable PCC–1, (The PCC–1 cable can be replaced with a Travel Charger ACH–6), and is connected to the Flash Prommer FPS–4S with the cable AXS–5.
NSE/B/C/K/M/W–1/3 Service Tools PAMS Technical Documentation Flash Prommer FPS–4S (Sales Pack) The Flash Prommer FPS–4S is used to update the main software of the phone. Updating is done by first loading the new MCU software from the PC to the flash prommer, and then loading the new SW from the prommer to the phone. When updating more than one phone in succession, the MCU software only needs to be loaded to the prommer once.
NSE/B/C/K/M/W–1/3 PAMS Technical Documentation Service Tools Security Box TDF–4 The Security Box TDF–4 is required for updating MCU software, and infra red testing. Note 1: TDF–4 is delivered in de–activated mode.
NSE/B/C/K/M/W–1/3 Service Tools PAMS Technical Documentation Service Audio Box JBA–4 The Service Audio Box JBA–4 is used between the Service Cable SCH–5, MBUS Cable DAU–9S, and Audio Cable ADS–1.
NSE/B/C/K/M/W–1/3 PAMS Technical Documentation Service Tools Service Cable SCH–5 The Service Cable SCH–5 is used between the phone and Service Audio Box JBA–4 (or modular T–adapter. It is also used between the phone and the Flash Loading Adapter FLA–5.
NSE/B/C/K/M/W–1/3 Service Tools PAMS Technical Documentation Warranty Cable SCH–6 The Warranty cable SCH–6 is used to connect two phones, and enables transfer of data (stored numbers etc.) from one phone to another.
NSE/B/C/K/M/W–1/3 PAMS Technical Documentation Service Tools Audio Cable ADS–1 Audio cable is an adapter routing AF signals (MIC/EAR) from 8 pin modular connector to two BNC connectors. It is used to connect JBA–4, SCH–5, and DAU–9S.
NSE/B/C/K/M/W–1/3 Service Tools PAMS Technical Documentation D15–D15 Cable AXS–5 The D15–D15 Cable AXS–5 is used to connect two 15 pin D connectors. e.g. between FLA–5 and FPS–4S.
NSE/B/C/K/M/W–1/3 PAMS Technical Documentation Service Tools DC Charging Cable PCC–1 The DC Cable PCC–1 is used e.g. to connect FLA–5 and TDF–4.
NSE/B/C/K/M/W–1/3 PAMS Technical Documentation Service Tools DC Cable SCB–3 The DC Cable SCB–3 is used to connect the Service Battery to the charger connection Vin of the phone when doing the charger calibration service procedure.
NSE/B/C/K/M/W–1/3 PAMS Technical Documentation Service Tools External Antenna Cable XRC–1B The External Antenna Cable is used to connect the transceiver to measuring equipment during servicing. Note: Typical attenuation at 900 MHz is 0.7 dB. Typical attenuation at 1800 MHz is 0.9 dB.
NSE/B/C/K/M/W–1/3 Service Tools PAMS Technical Documentation Light Flash FLC–5 (Sales Pack) The sales pack includes: – Light Flash Cable FLC–5 – Modular Cable XCM–1 – Light Flash PC SW 0770107 4626131 0774094 Sale package code Light Flash FLC–5: 0081263 View of FLC–5 Page 20 Original 10/98
NSE/B/C/K/M/W–1/3 PAMS Technical Documentation Service Tools MBUS Cable DAU–9S The MBUS Cable DAU–9S has a modular connector, and is used with the service Audio Box JBA–4, or a modular T–adapter.
NSE/B/C/K/M/W–1/3 Service Tools PAMS Technical Documentation MBUS Cable DAU–9P The MBUS Cable DAU–9P has a phone system connector, and is used between the phone and external devices.
NSE/B/C/K/M/W–1/3 PAMS Technical Documentation Service Tools Power Cable PCS–1 The Power Cable PCS–1 is used to connect the module jigs JBT–1 and JBS–19 to an external power supply. Can be used with FPS–4 also.
NSE/B/C/K/M/W–1/3 PAMS Technical Documentation Service Tools Modular T–adapter The modular T–adapter is a suitable branching unit to provide the needed parallel modular connections.
NSE/B/C/K/M/W–1/3 PAMS Technical Documentation Service Tools SW Security Device PKD–1 SW security device is a piece of hardware enabling the use of the service software when connected to the parallel (LPT) port of the PC. Whitout the dongle present it is not possible to use the service software. Printer or any such device can be connected to the PC through the dongle if needed.
NSE/B/C/K/M/W–1/3 Service Tools PAMS Technical Documentation This page intentionally left blank.