User Guide

PAMS
Technical Documentation
NME–3
Service Software Instructions
Page 30
Issue 1 10/99
Front End On check box:
This selection allows user to change whether the Front End amplifier is On or Off.
AGC edit box (ALT+F):
This selection allows user to edit AGC absolute value (value from A/D converter).
AGC value is shown only when its value is controlled by PC. When Active Unit has value
RX and Operation Mode is continuous, AGC is controlled by PC except when next ad-
justment functions are activated:
RSSI Calibration
AFC Diagram
Apply button (ALT+A):
Accepts entered values and validates them. After validation application sends corre-
sponding messages to ME. Closes dialog and updates Info Window.
Note! Active Unit and Operation mode are not send with because they are activated im-
mediately.
Set Defaults button (ALT+S):
Sets current values as default Rf Controls values.
Get Defaults button (ALT+E):
Gets default Rf Controls values as current values.
The next automatic selection is made when Quick testing function is ended:
Active Unit = RX
Update RF Information window
The next table shows the dialog’s properties on different situations:
ACTIVE UNIT = TX:
TX Data Type: Updated
AGC values: Greyed
Monitoring Channel: Greyed
OPERATION MODE = BURST:
TX Power Level: Updated
Continuous Mode Channel: Greyed
Channel: Updated
ACTIVE UNIT = RX:
TX Data Type: Greyed
TX Power Level: OFF, Greyed
OPERATION MODE = BURST:
AGC values: Greyed
Continuous Mode Channel: Greyed
Channel: Updated
Monitoring Channel: Updated
OPERATION MODE = CONT: