User Guide

PAMS
Technical Documentation
NME–3
Troubleshooting
Page 4
Issue 1 10/99
Radiounit failures
This chapter describes how to find failures in the Radiounit:
Radiounit doesn’t Powerup
Connect the Radiounit to +12V while ignition sense is switched off and
look to see if the Leds are turned ON for a short time
If they don’t turn on at all,
check the current consumtion, if it is about 300– 400uA the wakeup
logic should be checked, if it is much less or more there is a Problem
in the powersupply
Check the status of all voltages
Check the status of the wakeup logic
If the Leds stay on,
Check the digital part
Check powerdown logic
If the LEDs go off as specifed and current is O.K.:
Try to wakeup the radiounit by turning Ignition sense ON,
if the Leds stay on go to the next step
if they don’t stay on or don’t turn on at all check the Ignition circuit
Try to wakeup the radiounit by pressing the powerbutton of the HS,
if the Leds stay on go on, try flashing the unit
if they don’t stay on or don’t turn on at all check the Powerbutton cir-
cuit