Turn unit over to the keymat side
2 screws (13) trough A cover
into B cover domes
(400 rpm, 30Ncm)
Verify that A and B cover are properly closed by
checking that the gap between them is constant all
arround the Handset
13
GAP
Clean window with compressed air
Pull window adhesive protection foil off the A cover
and ensure, that the adhesive foil does not lift at the
finger lift side.
Press window (1) to A cover, top side first
Press the window down till it clips home
Press down the window to ensure fixation to B
cover
Attach protection foil to mounted window
1