Remote Interface
Remote Interface allows all manual adjustments to be controlled. The
results of the VDA measurements (AMC & CRM) and the result of
detecting the DC voltage level in the HFMIC path, are available as output
on the interface.
Use a PC to control the JBD–2 from the IEC–to–Parallel interface.
For example: “ICS 4863 - GPIB Parallel Interface”
JBD–2
Remote connector
ICS 4863
Parallel
IEEE–488
PC
IEC–
Bus Connector
Figure 18. Remote Interface
To activate the remote control, the remote line “REMOTE_EN” has to be
set to logical level high (+5V).
The different audio paths can be selected with the three BCD coded
remote lines RM_SYSTEM, RM_MODE1 and RM_MODE2.
Table 2. Significance of the RM_SYSTEM,RM_MODE1,RM_MODE2
Remote lines Selected audio mode
RM_MODE2 RM_MODE1 RM_SYSTEM
0 0 0 SYSTEM
0 0 1 MODE1
0 1 0 MODE2
0 1 1 MODE3
1 0 0 MODE4
1 0 1 MODE5
1 1 X reserved
With the input lines RM_FLS1 and RM_TEST will be selected the
differently operating modes of the JBD–2 box.
Table 3. Significance of the RM_FLS1, RM_TEST
Remote lines Selected operating modes
RM_FLS1 RM_TEST
0 0 Operating mode FLASH
0 1 Operating mode TEST
1 0 Operating mode FLS1
1 1 reserved