Figure 54 RM-198 baseband functional block diagram
Absolute maximum ratings
Signal Min Nom Max
Uni
t
Notes
Battery voltage (idle) -0.3 +4.5 V Battery voltage maximum value is
specified during charging is active
Battery voltage (Call) +4.3 V Battery voltage maximum value is
specified during charging is active
Charger input voltage -0.3 +16V V
Back-Up supply voltage 0 2.5 2.7 V Maximum capacity of the backup
power supply assumed to be 4 µAh.
Phone modes of operation
Mode Description
NO_SUPPLY (dead) mode means that the main battery is not present or its voltage is too low (below
EM ASIC (N2200) master reset threshold) and that the back-up battery voltage is too
low.
BACK_UP The main battery is not present or its voltage is too low but back-up battery voltage is
adequate and the 32kHz oscillator is running (RTC is on).
RM-198
System Module Nokia Customer Care
Issue 1 COMPANY CONFIDENTIAL Page 8 –7