User Guide
RM-94
Nokia Customer Care 6(b) - RF Troubleshooting
8 COMPANY CONFIDENTIAL Issue 1 04/2005
Copyright © 2005 Nokia. All Rights Reserved.
(The example below shows a screen shot in GSM900!)
Make the following settings on your signal generator:
Frequencies:
• GSM 900: 942.46771 MHz (channel 37+ 67.710 kHz offset)
• GSM 1800: 842.86771 MHz (channel 700 + 67.710 kHz offset)
• GSM 1900: 1960.06771 MHz (channel 661+ 67.710 kHz offset)
RF power level:
• – 80 dBm @ the antenna connector of the phone/ test jig
(remembering to compensate for the cable and jig attenuation).
Click on <Read now> in RSSI reading.
The resulting RSSI level shall be – 80 dBm +/– 0.5 dB in each band.
Measuring RX performance using SNR measurement
Start Phoenix Service Software and open FBUS connection.
Select Scan Product Ctrl-R
Wait until the phone information is shown in the lower right corner of the screen.
Set operating mode to <local mode>.
Select Testing T
RF Controls F
Select Band GSM 900 or GSM1800 or GSM1900
Active unit RX