User Guide
Issue 1 04/2005 COMPANY CONFIDENTIAL 27
Copyright © 2005 Nokia. All Rights Reserved.
RM-94
6(b) - RF Troubleshooting Nokia Customer Care
The setup should now look like this:
Now the measurement equipment should detect the following output signal of the phone:
P
out
= +23dBm @ 1880 MHz
If this is not the case, then go to the GMSK fault finding chart for GSM1900 transmitter.
EDGE
Set operating mode to local mode.
Select Testing RF Controls
Wait until the RF Controls window pops up.
Select Band GSM 1900
Active unit TX
Operation mode Burst
RX/TX Channel 661
TX Power Level 5
TX Data Type All1
Edge On