User Guide

Issue 1 04/2005 COMPANY CONFIDENTIAL 23
Copyright © 2005 Nokia. All Rights Reserved.
RM-94
6(b) - RF Troubleshooting Nokia Customer Care
The setup should now look like this:
Now the measurement equipment should detect the following output signal of the phone:
P
out
= +23dBm @ 1747.8 MHz
If this is not the case, then go to the GMSK fault finding chart for GSM1800 transmitter.
EDGE
Set operating mode to local mode.
Select Testing RF Controls
Wait until the RF controls window pops up.
Select Band GSM 1800
Active unit TX
Operation mode Burst
RX/TX Channel 700
TX Power Level 5
TX Data Type All 1
Edge On