User Guide

Issue 1 03/2005 COMPANY CONFIDENTIAL 7
Copyright © 2005 Nokia. All Rights Reserved.
RM-31
6(b) - RF Troubleshooting Nokia Customer Care
Receiver Verification and Troubleshooting
General instructions for RX troubleshooting
Connect the phone to a PC, which has Phoenix Service Software and a dongle installed, using
either
repair jig and DAU-9S (RS232) cable or
repair jig and XCS-4 cable via FPS-8 Flash Box or
DAU-9T cable (RS232).
Connect the phone to a power supply (DC voltage: 3.6V, max. current: 3A) and an RF signal
generator. Switch the phone on.
Start Phoenix Service Software and open FBUS connection.
Select Scan Product Ctrl-R
and wait until the phone information (RM-31) is shown in the lower right corner of the screen.
Follow the instructions below.
Measuring RX I/Q signals using RSSI reading
Start Phoenix Service Software and open FBUS connection.
Select Scan Product Ctrl-R
Wait until the phone information is shown in the lower right corner of the screen.
Set the operating mode to local mode
Select Testing T
RF Controls F
Select Band GSM850 or GSM1800 or GSM1900
Active unit RX
Operation mode Burst
RX/TX Channel 190 or 700 or 661
Select Testing T
RSSI reading
R
In the RSSI Reading window, the <measuring mode> shall be set on Sum vector and the
<reading mode> on Continuous.
The set up should now look like this: