User Guide

Issue 1 01/2005 COMPANY CONFIDENTIAL 57
Copyright © 2005 Nokia. All Rights Reserved.
RM-30
3 - Service Software and Tuning Instructions Nokia Customer Care
Adjust DAC Values for all power levels according to the target values:
The power levels may differ from the target levels mentioned. Make sure that the output power
for Power Level 0 is equal or lower than 1dB below the saturation output power. Determine the
saturation power by setting the DAC Value to its maximum, for example, adjust the DAC Value
to 29.7dBm for Power Level 0 if the saturation output power is only 30.7dBm.
Due to high gain slope, you have to ensure, that especially the lower power levels meet the
target values and correct them if needed.
Check if all levels match the target values, correct if necessary and then press < Save & Con-
tinue >.
Tx power level tuning GSM1800 & GSM1900 in EDGE mode
On the popped up window, press ok.
Power level Power (dBm)
0 30
11 8
15 0
Base level -27