User Guide

Nokia Customer Care Troubleshooting - Baseband
6015/6015i/6016i/6019i (RH-55), 6012 (RM-20)
Issue 1 - Revision 002 09/2004 ©2004 Nokia Corporation Company Confidential Page 21
Charging Operation
Battery
The phone uses a Lithium-Ion cell battery (BL-6C) with a capacity of 1070 mAh. Reading
a resistor inside the battery pack on the BSI line indicates the battery size. An NTC
resistor close to the SIM connector measures the phone’s temperature on the BTEMP
line.
C107 "The Phone MCU can not start Secondary code
correctly."
UPP
C586 "The erasing status response from the Phone
informs about fail."
Flash
C686 "The programming status response from the
Phone informs about fail."
Flash
Cx81 "The Prommer has detected a checksum error
in the message, which it has received from the
Phone."
FbusTx from UPP->UEM->Prommer
Cx82 "The Prommer has detected a wrong ID byte in
the message, which it has received from the
Phone."
FbusTx from UPP->UEM->Prommer
A204
Cx83
Cx84
Cx85
"The flash manufacturer and device IDs in the
existing algorithm files do not match with the
IDs received from the target phone."
"The Prommer has not received phone
acknowledge to the message."
"The phone has generated NAK signal during
data block transfer."
"Data block handling timeout"
Flash
UPP
VIO/VANA?
Signals between UPP-Flash
Mbus from Prommer->UEM->UPP(MbusRx)
FbusRx from Prommer->UEM->UPP
FbusTx from UPP->UEM->Prommer
Cx87 "Wrong MCU ID." RFClock
UPP(Vcore)
Startup
for
flashing
Required startup for flashing Vflash1
VBatt
Table 3: Flash Programming Error Codes (Continued)
Error Description Not Working Properly