Reference voltages for regulators require external 1uF capacitors. Vref25RF is reference
voltage for VR2 regulator; Vref25BB is reference voltage for VANA, VFLASH1, VFLASH2,
VR1 regulators; Vref278 is reference voltage for VR3, VR4, VR5, VR6, VR7 regulators;
VrefRF01 is reference voltage for VIO, VCORE, VSIM regulators, and for RF.
The baseband is powered from five different UEM regulators:
Table 2 includes the UEM voltage regulators used by the RF.
Table 1: Baseband Regulators
Regulator
Maximum
Current (mA)
Vout (V) Notes
VCORE
DC/DC
300 1.35 The power-up default value is 1.35V. The output voltage is
selectable: 1.0V/1.3V/1.5V/1.8V.
VIO 150 1.8 Enabled always except during power-off mode
VFLASH1 70 2.78 Enabled always except during power-off mode
VFLASH2 40 2.78 Enabled only when data cable is connected
VANA 80 2.78 Enabled only when the system is awake (off during sleep
and power-off modes)
VSIM 25 3.0 Enabled during power-up mode and scanning for a SIM
card
Table 2: RF Regulators
Regulator
Maximum
Current (mA)
Vout (V) Notes
VR1A 10 4.75 Enabled when the receiver is on
VR1B 10 4.75 Enabled when the transmitter is on
VR2 100 2.78 Enabled when the transmitter is on
VR3 20 2.78 Enabled when SleepX is high
VR4 50 2.78 Enabled when the receiver is on
VR5 50 2.78 Enabled when the receiver is on
VR6 50 2.78 Enabled when the transmitter is on
VR7 45 2.78 Enabled when the receiver is on
Table 3: Regulator Descriptions
Regulator Description
VANA Supplies internal and external analog circuitry of the BB. This regulator is disabled in sleep mode.
Vflash1 Supplies the LCD and the digital parts of the UEM ASIC. This regulator is enabled during startup
and enters low Iq-mode in sleep mode.