User Guide
6015/6015i/6016i/6019i (RH-55), 6012 (RM-20)
Troubleshooting - RF Nokia Customer Care
Page 44 ©2004 Nokia Corporation Company Confidential Issue 1 - Revision 002 09/2004
Use the following steps to troubleshoot the synthesizer using Phoenix:
1. On the Phone Control dialog box, click the LOCAL button in the Phone State
area to put the phone into Local Mode.
Figure 35: Phone Control dialog box
2. Select the following values on the RF Main Mode dialog box:.
19.2 MHZ VCTCXO Reference Clock
The VCTCXO frequency is a 19.2MHz reference signal. Without 19.2MHz, the phone does
not power up. This signal goes to Batman, Jupiter, the UHF PLL, and also to the UPP. Use
a high impedance probe to check for the presence of the signal at the following points:
• F_REF_TX, clock reference to Jupiter, should be ~ -9 dBm
• F_REF_RX, clock reference to Batman, should be ~ -9 dBm
• CLK10M2_UPP, clock reference to UPP, should be ~ -9 dBm and ~2 dB less in the
other side on R517
Table 10: RF Main Mode Dialog Box Settings
Synthesizer Band Mode Channel Notes
UHF
Cell RX/TX 384 Allows for checking power to both RX and TX circuits.
PCS RX/TX 600
RX VHF RX One band is enough.
TX VHF Cell
PCS
RX/TX 384
600