Troubleshooting - RF Nokia Customer Care
Page 38 ©2004 Nokia Corporation Company Confidential Issue 1 - Revision 002 09/2004
Receiver Logic Input Voltages
Following are the measure logic levels for the RX front end (N750). See Figure 22 on
page 29 for the manual selection of logic states using Phoenix.
Table 7 includes the logic level values for the RX front end.
If the logic levels are significantly off (+/- 0.2 V), replace Alfred (N750) and re-measure.
If the voltages are still out of specifications, refer to the Baseband Troubleshooting
chapter.
Table 7: RX Front-end (N750) Logic Levels
Mode
Logic Input Voltages
IF_SEL BAND GAIN_CTL
Cell CDMA High Gain 0 V 0.1 V 2.75 V
Cell CDMA Low Gain 0 V 0.1 V 0 V
PCS CDMA High Gain 0 V 2.68 V 2.75 V
PCS CDMA Low Gain 0 V 2.68 V 0 V
AMPS High Gain 2.76 V 0.1 V 2.76 V
AMPS Low Gain 2.76 V 0.1 V 0 V