User Guide
Nokia Customer Care Troubleshooting - RF
6015/6015i/6016i/6019i (RH-55), 6012 (RM-20)
Issue 1 - Revision 002 09/2004 ©2004 Nokia Corporation Company Confidential Page 35
Table 4 includes the descriptions and values for the RX RF troubleshooting test points
shown in Figure 29.
Receiver IF
Figure 30: Receiver IF troubleshooting test points
Table 4: Receiver RF Troubleshooting Values
Test
Point
Description Value
1 RX LO (from VCO) 1009.62MHz at -8 dBm
2088.1MHz at -14 dBm
2 Cell Channel 384 (from duplexer) 881.52MHz at -31 dBm
3 Cell Channel 384 (to RF SAW) 881.52MHz at -20 dBm (HG)
881.52MHz at -36 dBm (LG)
4 PCS Channel 600 (from duplexer) 1960MHz at -40 dBm
5 PCS Channel 600 (to RF SAW) 1960MHz at -30 dBm (HG)
1960MHz at -45 dBm (LG)
6 IF MIX OUT (from Alfred) 128.1MHz at -20 dBm (HG)
128.1MHz at -37 dBm (LG)
7 IFA IN (to Alfred) 128.1MHz at -15 dBm (HG)
128.1MHz at -30 dBm (LG)
1
4
3
2
5
6
7