User Guide
6015/6015i/6016i/6019i (RH-55), 6012 (RM-20)
Troubleshooting - RF Nokia Customer Care
Page 20 ©2004 Nokia Corporation Company Confidential Issue 1 - Revision 002 09/2004
Figure 14: Bottom side TX DC probe points
Table 1 shows the TX DC probe points for the bottom and top sides of the PWB.
Table 1: TX DC Probe Points
Test Point Description Value
1 Power detector VR2 2.76V
2 Vbatt PCS*
3 AGC 2 0.1 to 1.8V
4 AGC 1 0.1 to 1.8V
5 TX IQ IN
TX IQ IN with oscilloscope
Approximately 1. 2V
Approximately 500 mV p-p
6VR6 2.8V
7VR1B 4.8V
8 TX UHF LO lock voltage 1.2V
9 Vbatt Cell*
10 Power detector output PCS:
1.9V at <5dBm
1.6V at 15dBm
0.8V at 25dBm
Cell:
1.9V at <5dBm
1.7V at 15dBm
1.3V at 25dBm
11 Vre fR F1 1.4 5V
11
12
13
14
15
16