User Guide
CONFIDENTIAL
10(11)
Product NPM-5 Repairhints
Customer Care Europa & Africa Introduction Version 1.0 Approved
2002 SCCE Training Group
Date 08.04.2002
npm_5_repair_v1_0.doc Checked by:
SCCE Training Group
Approved by:
SCCE
Maverick specific CMT faults
Slow key function
When reaction on a keypress takes around 3 seconds, measure following voltage:
Check VREF=1.5 VDC at C109. If the voltage is lower than 1.4 VDC, probably the capacitor C109 is faulty.
If the fault persists after changing C109, check VREF line between Ccont N201 and Cobba N100 for disconnections or shorts.
Also refer to chapter CMT (MA4) faults.
CMT (MA4) faults
Note! For CMT (MA4) module faults refer to 3310/3330 Repairhints. Only 5510 specific CMT faults are shown in these
5510 Repairhints.