PAMS Technical Documentation NSM–5 Series Transceivers Service Tools Issue 1 02/2002 Nokia Corporation
NSM–5 Service Tools PAMS Technical Documentation CONTENTS Service Box JBU-6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of JBU-6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RF Adapter RAF-5 for Service Box JBU-6 . . . . . . . . . . . . . . . . . . . . . Service Box JBU-6 cont. . . . . . . . . . . . . . . . .
PAMS Technical Documentation NSM–5 Service Tools Service Cable AXS-4U . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of AXS-4U . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D15-D15 Cable AXS-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Code . . . . . . . . . . . . . . . . . .
NSM–5 Service Tools PAMS Technical Documentation FLS-4 POS (Point Of Sale) Flash Device (Sales Pack) . . . . . . . . . . . . . Product Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of FLS-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NSM–5 Service Tools PAMS Technical Documentation Service Box JBU-6 The Service Box JBU-6 is used: - to make connection between transceiver and FLA-5/7 for flashing - to help functional tests - to enable connection to test/measurument devices - to generate accurate 4.1 and 8.4 voltage for Vbatt and Vin/Vchar lines - to generate accurate 500mA current for charging calibration Vin line - to generate 10 ms IBI-pulse to BTMP-line NOTE: JBU-6 cover should be closed during measurements.
NSM–5 Service Tools PAMS Technical Documentation Service Box JBU-6 cont. Pinset Cable SCD-6 for Service Box JBU-6 Spare part for JBU-6.
NSM–5 Service Tools PAMS Technical Documentation Test Jig MJS-9 The Test Jig MJS-9 is used for repair of system/RF module*. The zoom in picture contains two changeable over voltage protection components: SM Fuse F2.0 A 32V 1206 F 001 T 5119002 (larger of the two) VWM 5.6V VC15.5 R 008 T 1825019 Product Code Module Jig MJS-9: 0770154 View of MJS-9 NOTE: RJ9 Connector Module information! *Note: Issue 1 02/2002 The nominal supply voltage for MJS-9 is +8.0 V. The supply voltage must not exceed +15.0 V.
NSM–5 Service Tools PAMS Technical Documentation Soldering Jig MJS-75 The Soldering Jig MJS-75 is used for soldering (in automatic soldering machines) and as a rework jig for system module, if special fixtures (like extra feet) are used.
NSM–5 Service Tools PAMS Technical Documentation Flash Battery BBF-1 The Flash Battery BBF-1 is used in place of the phone’s normal battery during flashing. The zoom in picture contains two changeable over voltage protection components: SM Fuse F2.0 A 32V 1206 F 001 T 5119002 (larger of the two) VWM 5.6V VC15.5 R 008 T 1825019 Product Code Flash Battery BBF-1: 0775206 View of BBF-1 *Note: Issue 1 02/2002 The nominal supply voltage for BBF-1 is +8.0 V. The supply voltage must not exceed +15.0 V.
NSM–5 Service Tools PAMS Technical Documentation Flash Loading Adapter FLA-10 The Falsh Loading Adapter FLA-10 is used in place of the phone’s normal battery during service, to supply a controlled operating voltage.
PAMS Technical Documentation NSM–5 Service Tools Battery Connector Extractor Tool SRT-3 The Battery Connector Extractor Tool is used to remove the battery connector from the frame.
NSM–5 Service Tools PAMS Technical Documentation Flash Loading Adapter FLA-7 (Sales Pack) The Flash Loading Adapter FLA-7 is used with the Service Battery BBD-3 and Service Cable SCH-5. Power is supplied to FLA-7 from the Flash Security Box TDF-4 via the DC cable PCC-1, (The PCC-1 cable can be replaced with a Travel Charger ACH-6), and is connected to the Flash Prommer FPS-4S with the cable AXS-5.
NSM–5 Service Tools PAMS Technical Documentation Flash Prommer FPS-4S (Sales Pack) The Flash Prommer FPS-4S is used to update the main software of the phone. Updating is done by first loading the new MCU software from the PC to the flash prommer, and then loading the new SW from the prommer to the phone. When updating more than one phone in succession, the MCU software only needs to be loaded to the prommer once.
NSM–5 Service Tools PAMS Technical Documentation Security Box TDF-4 The Security Box TDF-4 is required for updating MCU software, and infra red testing. Note 1: TDF-4 is delivered in de-activated mode.
NSM–5 Service Tools PAMS Technical Documentation Service Cable AXS-4 The D9-D9 Service Cable AXS-4 is used to connect two 9 pin D connectors e.g. between PC and TDF-4 seurity box. Cable lenght is 2 meters.
NSM–5 Service Tools PAMS Technical Documentation Service Cable AXS-4U The D9-D9 Service Cable AXS-4U is used to connect two 9 pin D connectors e.g. between PC’s serial port and FLS-2D. Cable length is 30 cm.
NSM–5 Service Tools PAMS Technical Documentation D15-D15 Cable AXS-5 The D15-D15 Cable AXS-5 is used to connect two 15 pin D connectors. e.g. between FLA-5/7 and FPS-4S.
NSM–5 Service Tools PAMS Technical Documentation MBUS Cable DAU-9S The MBUS Cable DAU-9S has a modular connector, and is used with the service Audio Box JBA-4, or a modular T-adapter.
NSM–5 Service Tools PAMS Technical Documentation DC Cable AXD-1 The DC Cable AXD-1 is used e.g. to connect FLA-7 and TDF-4.
NSM–5 Service Tools PAMS Technical Documentation DC Charging Cable PCC-1B The DC Cable PCC-1 is used e.g. to connect FLA-5 and TDF-4.
NSM–5 Service Tools PAMS Technical Documentation Power Cable PCS-1 The Power Cable PCS-1 is used to connect the module jigs MJS-9 and JBU-6 to an external power supply. Can be used with FPS-4 also.
NSM–5 Service Tools PAMS Technical Documentation DC Cable SCB-3 The DC Cable SCB-3 is used to connect the Service Battery to the charger connection Vin of the phone when doing the charger calibration service procedure.
NSM–5 Service Tools PAMS Technical Documentation Service Cable XMS-3 XMS-3 is a modular cable for flashing and service purposes.
NSM–5 Service Tools PAMS Technical Documentation RF Cable XRF-1 RF cable XRF-1 is used to connect RF Test adapter AAT-8 or Test frame MJS-9 to RF measurement equipment..
NSM–5 Service Tools PAMS Technical Documentation RF Cable XRS-3 RF cable XRS-3 is used to connect JBU-6 Service Box to RF measurement equipment.
NSM–5 Service Tools PAMS Technical Documentation Modular T-adapter The modular T-adapter is a suitable branching unit to provide the needed parallel modular connections.
PAMS Technical Documentation NSM–5 Service Tools Modular Cable Jack Connector The Modular Cable Jack Connector is a suitable for connecting two Service Flash Batteries (BBF-1) together in Warranty Transfer. Product Code Modular Cable Jack Connector (available eg.
NSM–5 Service Tools PAMS Technical Documentation SW Security Device PKD-1 SW security device is a piece of hardware enabling the use of the service software when connected to the parallel (LPT) port of the PC. Whithout the dongle present it is not possible to use the service software. Printer or any such device can be connected to the PC through the dongle if needed.
NSM–5 Service Tools PAMS Technical Documentation FLS-4 POS (Point Of Sale) Flash Device (Sales Pack) FLS-4 is a dongle and flash device incorporated into one package, developed specifically for POS use.
NSM–5 Service Tools PAMS Technical Documentation This page intentionally left blank.