User Guide

NSM–5
Service Software Instructions
PAMS Technical Documentation
Page 42
Issue 1 02/2002
Nokia Corporation
Channel edit box (ALT+H):
User can enter here channel number that is used for both
transmission and receiving. The frequency of the selected
channel is shown after selection.
Monitoring Channel edit box (ALT+M):
This field selects neighbour monitoring channel. The frequency
of the selected channel is shown after selection.
Continuous Mode Channel edit box (ALT+C):
To this edit box user can type continuous mode channel which
may have all channel numbers.
The used frequency depends on the Active Unit. If Active Unit
is RX, then RX frequency is used, else TX frequency. The fre-
quency of the selected channel is shown after selection.
Gain Step Value edit box (ALT+L):
This selection allows user to set up the receiver gain step in
continuous mode. There are nine (0...8) steps. In the burts
mode selection is automatic.
AFC edit box (ALT+F):
This selection allows user manually tune the 26 MHz clock.
Limits are –1023...–1024
Apply button (ALT+A):
Accepts entered values and validates them. After validation ap-
plication sends corresponding messages to ME. Closes dialog
and updates Info Window.
Note! Active Unit and Operation mode are not send with because they are
activated immediately.
Set Defaults button (ALT+S):
Sets current values as default Rf Controls values.
Get Defaults button (ALT+U):
Gets default Rf Controls values as current values.
The next automatic selection is made when Quick testing function is ended:
Active Unit = RX
Update RF Information window
The next table shows the dialog’s properties on different situations:
ACTIVE UNIT = TX:
TX Data Type: Updated
AGC values: Greyed
Monitoring Channel: Greyed
OPERATION MODE = BURST:
TX Power Level: Updated