fed via UI connector to avoid damage of the CCONT during production line
flashing ( 12V fed to FLASH Vpp from the production tester ).
Pin Name Parameter Min Typ Max Unit Remark
1 VIN Charging 6.8 7.8 8.8 V Supply Voltage,Current
limited to 850 mA
11 MBUS Serial clock
from the
Prommer
2.0
0
2.8
0.8
V Prommer detection and
Serial Clock for synchro-
nous communication
12 FBUS_RX Serial data
from the
Prommer
2.0
0
2.8
0.8
V Receive Data from
Prommer to Baseband
13 FBUS_TX Data ac-
knowledge to
the Prommer
2.0
0
2.8
0.8
V Transmit Data from Base-
band to Prommer
14 GND GND 0 0 V Supply ground
Battery connector
The BSI contact on the battery connector is used to detect when the bat-
tery is to be removed to be able to shut down the operations of the SIM
card before the power is lost if the battery is removed with power on. The
BSI contact in the battery pack should be shorter than the supply power
contacts to give enough time for the SIM shut down.
A vibra alerting device is used for giving silent signal to the user of an in-
coming call. The device is not placed in the phone but it will be added to a
special battery pack. The vibra is controlled with a PWM signal by the
MAD via the BTEMP battery terminal.
SIM card connector
Pin Name Parameter Min Typ Max Unit Notes
1 GND GND 0 0 V Ground
2 VSIM 5V SIM Card
3V SIM Card
4.8
2.8
5.0
3.0
5.2
3.2
V Supply voltage
3 DATA 5V Vin/Vout
3V Vin/Vout
4.0
0
2.8
0
”1”
”0”
”1”
”0”
VSIM
0.5
VSIM
0.5
V SIM data
Trise/Tfall max 1us
4 SIMRST 5V SIM Card
3V SIM Card
4.0
2.8
”1”
”1”
VSIM
VSIM
V SIM reset
5 SIMCLK Frequency
Trise/Tfall
1.625 3.25 5.0
25
MHz
ns
SIM clock