User Guide
PAMS
Technical Documentation
NSB–1/3
Service Software Instructions
Page 39
Original 06/98
Note that power–off test have no values, because if test has been
passed, power has been turned off. If power–off test fails a special error
message window is shown. If no response is received to power off test
message in a few seconds, the user is informed by special info window,
where user is asked to turn the power on and then press the return key.
Note also that power–off test (if passed) turns power off and power
should be reconnected by using the phones keypad after the successful
test. After the power has been connected to phone, the normal start–up
routines are made and the self–test results are shown in the MCU self–
tests menu (i.e. all other than power–up self–tests are in
Not executed
state after the power–up routines).
Run button (ALT+R or ENTER):
User can select desired test from list and hit Run button. When user se-
lects test to be run the text
RUNNING...
is shown in test state field and
test is run. When results are received the test state field is updated ac-
cording to the result.
If no response was received in the defined time, a
error message box
will
be shown and the test state is changed to
No response
. Phone is set to
local mode if it is not already there.
Run A
ll button (ALT+A):
User can run all listed tests. The text
RUNNING...
is shown in test state
field and test is run. When results are received the test state field is up-
dated according to the result. When state field is updated application
moves to next test and repeats previous cycle. Phone is set to local mode
if it is not already there.